中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup

文献类型:期刊论文

作者Leitner M ; Fantner GE ; Fantner EJ ; Ivanova K ; Ivanov T ; Rangelow I ; Ebner A ; Rangl M ; Tang J ; Hinterdorfer P
刊名micron
出版日期2012
卷号43期号:12页码:1399-1407
关键词SINGLE-MOLECULE RECOGNITION NUCLEAR-PORE COMPLEX S-LAYER PROTEINS ATOMIC-FORCE REAL-TIME SIMULTANEOUS TOPOGRAPHY HUMAN RHINOVIRUS AFFINITY-TAGS MICROSCOPY VISUALIZATION
ISSN号0968-4328
通讯作者hinterdorfer p
中文摘要in this study, we demonstrate the increased performance in speed and sensitivity achieved by the use of small afm cantilevers on a standard afm system. for this, small rectangular silicon oxynitride cantilevers were utilized to arrive at faster atomic force microscopy (afm) imaging times and more sensitive molecular recognition force spectroscopy (mrfs) experiments. the cantilevers we used had lengths between 13 and 46 mu m, a width of about 11 mu m, and a thickness between 150 and 600 nm. they were coated with chromium and gold on the backside for a better laser reflection. we characterized these small cantilevers through their frequency spectrum and with electron microscopy. due to their small size and high resonance frequency we were able to increase the imaging speed by a factor of 10 without any loss in resolution for images from several mu m scansize down to the nanometer scale. this was shown on bacterial surface layers (s-layer) with tapping mode under aqueous, near physiological conditions and on nuclear membranes in contact mode in ambient environment. in addition, we showed that single molecular forces can be measured with an up to 5 times higher force sensitivity in comparison to conventional cantilevers with similar spring constants. (c) 2012 elsevier ltd. all rights reserved.
收录类别SCI收录期刊论文
语种英语
WOS记录号WOS:000308680900025
公开日期2013-03-18
源URL[http://ir.ciac.jl.cn/handle/322003/47822]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Leitner M,Fantner GE,Fantner EJ,et al. Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup[J]. micron,2012,43(12):1399-1407.
APA Leitner M.,Fantner GE.,Fantner EJ.,Ivanova K.,Ivanov T.,...&Hinterdorfer P.(2012).Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup.micron,43(12),1399-1407.
MLA Leitner M,et al."Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup".micron 43.12(2012):1399-1407.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。