中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution

文献类型:期刊论文

作者Wang ZZ; Liu W(刘巍); Wang CX; Kan Q; Chen S(陈涉); Chen HD
刊名SENSORS AND ACTUATORS B-CHEMICAL
出版日期2013-05-01
卷号181页码:221-226
通讯作者邮箱cxwang@semi.ac.cn
关键词Surface plasmon resonance Ellipsometry Ion selective electrode Image contrast
ISSN号0925-4005
产权排序[Wang, Zhenzhen; Wang, Chunxia; Kan, Qiang; Chen, Hongda] Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China; [Wang, Zhenzhen] Tsinghua Univ, Dept Phys, Beijing 100084, Peoples R China; [Liu, Wei; Chen, She] Chinese Acad Sci, Inst Mech, Dept Natl Micrograv Lab, Beijing 100083, Peoples R China
通讯作者Wang, CX (reprint author), Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China.
合作状况国内
中文摘要Cobalt-based ion selective electrode (ISE) is one of the key methods for phosphate detection. In this paper, surface plasmon resonance (SPR) enhanced ellipsometric analysis method has been used to monitor the electrochemical reaction process at Co ISE sensor surface and the mass consumption of sensitive electrode membranes. An Au-Co bilayer film is designed as optical detection interface. In order to obtain detectable reflection intensity variation with Co thickness, Au film and Co film thickness are optimized at TM polarization state. According to the calculation results, 50 nm Au film is formed on glass substrate by electron beam evaporation. Then cobalt film with thickness of about 20 nm is grown on gold film by electrochemical deposition method. Ellipsometric measurements were performed at SPR angle 59. The consuming process of Co film reacting with dissolved oxygen in deionized water has been obtained by monitoring the change of reflection intensity.
学科主题交叉与边缘领域的力学
分类号二类/Q1
收录类别SCI ; EI
资助信息National Basic Research of China [2009CB320300, 2010CB934104, 2011CB933203, 2011CB933102]; Nation Natural Foundation of China [61036009, 60978067]
原文出处http://dx.doi.org/10.1016/j.snb.2013.01.044
语种英语
WOS记录号WOS:000317941100032
公开日期2013-05-31
源URL[http://dspace.imech.ac.cn/handle/311007/47259]  
专题力学研究所_国家微重力实验室
推荐引用方式
GB/T 7714
Wang ZZ,Liu W,Wang CX,et al. Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution[J]. SENSORS AND ACTUATORS B-CHEMICAL,2013,181:221-226.
APA Wang ZZ,刘巍,Wang CX,Kan Q,陈涉,&Chen HD.(2013).Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution.SENSORS AND ACTUATORS B-CHEMICAL,181,221-226.
MLA Wang ZZ,et al."Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution".SENSORS AND ACTUATORS B-CHEMICAL 181(2013):221-226.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。