中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Multi channel micro neural probe fabricated with SOI

文献类型:会议论文

作者Wang SJ (Wang Shujing) ; Pei WH (Pei Weihua) ; Guo K (Guo Kai) ; Gui Q (Gui Qiang) ; Wang Y (Wang Yu) ; Zhang X (Zhang Xu) ; Tang J (Tang Jun) ; Chen HD (Chen Hongda)
出版日期2009
会议名称icme international conference on complex medical engineering
会议日期apr 09-11, 2009
会议地点tempe, az
关键词MICROELECTRODE ARRAYS
页码161-164
通讯作者pei, wh, chinese acad sci, inst semicond, state key lab integrated optoelect, beijing 100083, peoples r china.
中文摘要extracellular neural recording requires neural probes having more recording sites as well as limited volumes. with its mechanical characteristic and abundant process method, silicon is a kind of material fit for producing neural probe. silicon on insulator (soi) is adopted in this paper to fabricate neural probes. the uniformity and manufacturability are improved. the fabricating process and testing results of a series of multi channel micro neural probes were reported. the thickness of the probe is 15 mu m-30 mu m. the typical impedance characteristics of the record sites are around 2m omega at 1k hz. the performance of the neural probe in-vivo was tested on anesthetic rat. the recorded neural spike was typically around 140 mu v. spike recorded from individual site could exceed 700 mu v. the average signal noise ratio was 7 or more.
英文摘要extracellular neural recording requires neural probes having more recording sites as well as limited volumes. with its mechanical characteristic and abundant process method, silicon is a kind of material fit for producing neural probe. silicon on insulator (soi) is adopted in this paper to fabricate neural probes. the uniformity and manufacturability are improved. the fabricating process and testing results of a series of multi channel micro neural probes were reported. the thickness of the probe is 15 mu m-30 mu m. the typical impedance characteristics of the record sites are around 2m omega at 1k hz. the performance of the neural probe in-vivo was tested on anesthetic rat. the recorded neural spike was typically around 140 mu v. spike recorded from individual site could exceed 700 mu v. the average signal noise ratio was 7 or more.; zhangdi于2010-03-09批量导入; zhangdi于2010-03-09批量导入; icme.; [wang, shujing; pei, weihua; guo, kai; gui, qiang; wang, yu; zhang, xu; tang, jun; chen, hongda] chinese acad sci, inst semicond, state key lab integrated optoelect, beijing 100083, peoples r china
收录类别其他
会议主办者icme.
会议录2009 icme international conference on complex medical engineering
会议录出版者ieee ; 345 e 47th st, new york, ny 10017 usa
学科主题人工智能
会议录出版地345 e 47th st, new york, ny 10017 usa
语种英语
ISBN号978-1-4244-3315-5
源URL[http://ir.semi.ac.cn/handle/172111/8364]  
专题半导体研究所_中国科学院半导体研究所(2009年前)
推荐引用方式
GB/T 7714
Wang SJ ,Pei WH ,Guo K ,et al. Multi channel micro neural probe fabricated with SOI[C]. 见:icme international conference on complex medical engineering. tempe, az. apr 09-11, 2009.