Implantable Microsystem for Wireless Neural Recording Applications
文献类型:会议论文
作者 | Zhang X (Zhang Xu) ; Pei WH (Pei Weihua) ; Huang BJ (Huang Beiju) ; Chen J (Chen Jin) ; Guan N (Guan Ning) ; Chen HD (Chen Hongda) |
出版日期 | 2009 |
会议名称 | icme international conference on complex medical engineering |
会议日期 | apr 09-11, 2009 |
会议地点 | tempe, az |
关键词 | SYSTEM |
页码 | 234-237 |
通讯作者 | zhang, x, chinese acad sci, inst semicond, state key lab integrated optoelect, beijing 100083, peoples r china. |
中文摘要 | a prototype microsystem is presented for wireless neural recording application. an inductive link was built for transcutaneous wireless power transfer and data transmission. total 16.5 mw power and 50 bps - 2.5 kbps command data can be received over 1 - 5 mhz with a distance of 0-10 mm. the integrated amplifiers were designed with a limited bandwidth for neural signals acquisition. the gain of 60 db was obtained by preamplifier at 7 hz - 3 khz. an integrated fm transmitter was used to transmit the extracted neural signals to external equipments with 0.374 - 2 mw power comsumption and a maximum data rate of 500 kbps at 100 mhz. all the integrated circuits modules except the power recovery circuit were tested or stimulated under a 3.3 v power supply, and fabricated in standard cmos processing. |
英文摘要 | a prototype microsystem is presented for wireless neural recording application. an inductive link was built for transcutaneous wireless power transfer and data transmission. total 16.5 mw power and 50 bps - 2.5 kbps command data can be received over 1 - 5 mhz with a distance of 0-10 mm. the integrated amplifiers were designed with a limited bandwidth for neural signals acquisition. the gain of 60 db was obtained by preamplifier at 7 hz - 3 khz. an integrated fm transmitter was used to transmit the extracted neural signals to external equipments with 0.374 - 2 mw power comsumption and a maximum data rate of 500 kbps at 100 mhz. all the integrated circuits modules except the power recovery circuit were tested or stimulated under a 3.3 v power supply, and fabricated in standard cmos processing.; zhangdi于2010-03-09批量导入; zhangdi于2010-03-09批量导入; icme.; [zhang, xu; pei, weihua; huang, beiju; chen, jin; guan, ning; chen, hongda] chinese acad sci, inst semicond, state key lab integrated optoelect, beijing 100083, peoples r china |
收录类别 | 其他 |
会议主办者 | icme. |
会议录 | 2009 icme international conference on complex medical engineering
![]() |
会议录出版者 | ieee ; 345 e 47th st, new york, ny 10017 usa |
学科主题 | 光电子学 |
会议录出版地 | 345 e 47th st, new york, ny 10017 usa |
语种 | 英语 |
ISBN号 | 978-1-4244-3315-5 |