中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Enzyme inhibitor screening by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique

文献类型:期刊论文

作者Tang ZM(唐忠美) ; Kang JW(康经武)
刊名Anal. Chem.
出版日期2006
卷号78期号:8页码:2514-2520
ISSN号0003-2700
其他题名Enzyme inhibitor screening by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique
通讯作者康经武
英文摘要A novel strategy for screening the enzyme inhibitors from the complex mixtures by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique is reported. The enzyme microreactor was prepared in two steps: First, the capillary wall was dynamically coated with a polycationic electrolyte hexadimethrine bromide (HDB) by simply flushing the column using the HDB solution. Subsequently, a plug of the enzyme solution was injected and incubated for 5 min to permit the enzyme molecules to immobilize on the positively charged coating via ionic binding. To demonstrate this strategy, angiotensin-converting enzyme (ACE) was employed as a model for the enzyme immobilization, inhibition study, and inhibitor screening. It has been proved that such a prepared immobilized ACE microreactor displays a high enough activity and stability. Furthermore, the immobilized enzyme microreactor could be easily renewed. The inhibition study or inhibitor screening was accomplished through the following procedure: (i) the substrate solution was injected and incubated within the microreactor for a short time span; (ii) subsequently, the voltage was applied to separate the product of the enzyme reaction from the unreacted substrate based on their different mobilities, the peak area of the product representing the enzyme activity; (iii) a certain amount of enzyme inhibitor or candidate compound was spiked into the substrate solution to assay the reduction of the immobilized enzyme activity. Thus, the inhibitors can be easily identified if the reduced peak area of the product is observed in electropherograms. Because the injection volume of the capillary was only 9.8 nL and the enzyme could be reusable, the assay cost could be dramatically reduced. The screening of a small compound library containing natural extracts and commercially available inhibitors was performed. The present approach has proved to be simple, rapid, and robust.
学科主题生命有机化学
收录类别SCI
原文出处http://dx.doi.org/10.1021/ac052030w
语种英语
WOS记录号WOS:000236948300007
公开日期2013-08-14
源URL[http://202.127.28.38/handle/331003/27643]  
专题上海有机化学研究所_上海有机化学研究所
推荐引用方式
GB/T 7714
Tang ZM,Kang JW. Enzyme inhibitor screening by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique[J]. Anal. Chem.,2006,78(8):2514-2520.
APA 唐忠美,&康经武.(2006).Enzyme inhibitor screening by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique.Anal. Chem.,78(8),2514-2520.
MLA 唐忠美,et al."Enzyme inhibitor screening by capillary electrophoresis with an on-column immobilized enzyme microreactor created by an ionic binding technique".Anal. Chem. 78.8(2006):2514-2520.

入库方式: OAI收割

来源:上海有机化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。