Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor

文献类型:期刊论文

作者Kou, Li-Juan1,2,3; Liang, Rong-Ning1,3; Wang, Xue-Wei1,2,3; Chen, Yan1,3; Qin, Wei1,3
刊名ANALYTICAL AND BIOANALYTICAL CHEMISTRY
出版日期2013-05-01
卷号405期号:14页码:4931-4936
关键词Molecularly imprinted polymers Ion-selective electrodes Bisphenol A Phenols
ISSN号1618-2642
产权排序[Kou, Li-Juan; Liang, Rong-Ning; Wang, Xue-Wei; Chen, Yan; Qin, Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Yantai 264003, Shandong, Peoples R China; [Kou, Li-Juan; Wang, Xue-Wei] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China; [Kou, Li-Juan; Liang, Rong-Ning; Wang, Xue-Wei; Chen, Yan; Qin, Wei] YICCAS, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Shandong, Peoples R China
通讯作者Qin, W (reprint author), Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Yantai 264003, Shandong, Peoples R China. wqin@yic.ac.cn
中文摘要The aim of this paper is to develop a potentiometric sensing methodology for sensitive and selective determination of neutral phenols by using a molecularly imprinted polymer as a receptor. Bisphenol A (BPA), a significant environmental contaminant, is employed as the model target. The BPA-imprinted polymer is synthesized by the semi-covalent technique and incorporated into a plasticized poly(vinyl chloride) membrane doped with the tridodecylmethylammonium salt. The present electrode shows a linear anionic potential response over the concentration range from 0.1 to 1 mu M with a detection limit of 0.02 mu M, and exhibits an excellent selectivity over other phenols. The proposed approach has been successfully applied to the determination of BPA released from real plastic samples. It offers promising potential in development of potentiometric sensors for measuring neutral phenols at trace levels.
英文摘要The aim of this paper is to develop a potentiometric sensing methodology for sensitive and selective determination of neutral phenols by using a molecularly imprinted polymer as a receptor. Bisphenol A (BPA), a significant environmental contaminant, is employed as the model target. The BPA-imprinted polymer is synthesized by the semi-covalent technique and incorporated into a plasticized poly(vinyl chloride) membrane doped with the tridodecylmethylammonium salt. The present electrode shows a linear anionic potential response over the concentration range from 0.1 to 1 mu M with a detection limit of 0.02 mu M, and exhibits an excellent selectivity over other phenols. The proposed approach has been successfully applied to the determination of BPA released from real plastic samples. It offers promising potential in development of potentiometric sensors for measuring neutral phenols at trace levels.
学科主题Biochemical Research Methods; Chemistry, Analytical
研究领域[WOS]Biochemistry & Molecular Biology ; Chemistry
关键词[WOS]SOLID-PHASE EXTRACTION ; MEMBRANE ; ELECTRODES ; MECHANISM ; SAMPLES ; WATER ; MILK
收录类别SCI
资助信息Instrument Developing Project of the Chinese Academy of Sciences [YZ201161]; National Natural Science Foundation of China [20977073, 41206087]; Taishan Scholar Program of Shandong Province [TS20081159]
原文出处10.1007/s00216-013-6877-2
语种英语
WOS记录号WOS:000318312400026
公开日期2013-08-15
源URL[http://ir.yic.ac.cn/handle/133337/6655]  
专题烟台海岸带研究所_中科院海岸带环境过程与生态修复重点实验室
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Yantai 264003, Shandong, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
3.YICCAS, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Shandong, Peoples R China
推荐引用方式
GB/T 7714
Kou, Li-Juan,Liang, Rong-Ning,Wang, Xue-Wei,et al. Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor[J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY,2013,405(14):4931-4936.
APA Kou, Li-Juan,Liang, Rong-Ning,Wang, Xue-Wei,Chen, Yan,&Qin, Wei.(2013).Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,405(14),4931-4936.
MLA Kou, Li-Juan,et al."Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 405.14(2013):4931-4936.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。