Influence of test model material on the accuracy of transient heat transfer measurements in impulse facilities
文献类型:期刊论文
作者 | Wang Q(汪球)3![]() ![]() ![]() |
刊名 | EXPERIMENTAL THERMAL AND FLUID SCIENCE
![]() |
出版日期 | 2019-06-01 |
卷号 | 104页码:59-66 |
关键词 | Heat transfer measurement Lateral heat conduction Shock tunnel Thermocouple Hypersonic |
ISSN号 | 0894-1777 |
DOI | 10.1016/j.expthermflusci.2019.02.013 |
通讯作者 | Wang, Qiu(wangqiu@imech.ac.cn) |
英文摘要 | The development of suitable heat-resistant materials and appropriate thermal structure design for a hypersonic aircraft requires highly precise heat transfer predictions. Unfortunately, existing techniques for measuring the transient heat flux by thermal sensors in impulse facilities are overly complex; any slight deviation from ideal conditions may lead to inaccuracy. In this study, the influence of different model materials leading to lateral heat conduction between model and sensor on the accuracy of heat flux measurements using type-E coaxial ther-mocouples was investigated. The behavior of the materials results to a deviation from the assumption of one-dimensional heat conduction more or less. The materials examined were stainless steel, aluminum, carbon steel, and polyamide, which are frequently used as model materials in ground tests. The influence of the model materials was estimated by comparing the heat flux derived from the junction temperature with the actual heat flux loading. Particular attention was paid to aluminum, which is extensively used as wind tunnel model material. An engineering-based approach is also presented to conduct high accuracy measurements. The results show that the difference in the thermal properties between the sensor and the model materials creates complicated lateral heat conduction between them; stainless steel 304 is suggest as the use of model material whenever high-accuracy heat transfer measurements are desired due to its similarity of the thermal properties to type-E sensors. The use of polyamide PA6 material resulted in a larger heat flux due to its smaller thermal effusivity and the aluminum and carbon steel led to lower heat fluxes due to their larger thermal effusivity. The deviation of either material increases over testing time. |
分类号 | 一类 |
WOS关键词 | SURFACE ; THERMOCOUPLES ; SENSOR |
资助项目 | China Scholarship Council ; National Natural Science Foundation of China[11402275] ; National Natural Science Foundation of China[11472280] |
WOS研究方向 | Thermodynamics ; Engineering ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000465055600006 |
资助机构 | China Scholarship Council ; National Natural Science Foundation of China |
其他责任者 | Wang, Qiu |
源URL | [http://dspace.imech.ac.cn/handle/311007/78702] ![]() |
专题 | 力学研究所_高温气体动力学国家重点实验室 |
作者单位 | 1.Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China 2.Rhein Westfal TH Aachen, Shock Wave Lab, D-52056 Aachen, Germany; 3.Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China; |
推荐引用方式 GB/T 7714 | Wang Q,Olivier H,Einhoff J,et al. Influence of test model material on the accuracy of transient heat transfer measurements in impulse facilities[J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE,2019,104:59-66. |
APA | 汪球,Olivier H,Einhoff J,李进平,&赵伟.(2019).Influence of test model material on the accuracy of transient heat transfer measurements in impulse facilities.EXPERIMENTAL THERMAL AND FLUID SCIENCE,104,59-66. |
MLA | 汪球,et al."Influence of test model material on the accuracy of transient heat transfer measurements in impulse facilities".EXPERIMENTAL THERMAL AND FLUID SCIENCE 104(2019):59-66. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。