Capability verification of the beam delivery system in the superficially-placed tumor therapy terminal at HIRFL

文献类型:期刊论文

作者Dai Zhong-Ying; Li Qiang; Xiao Guo-Qing; Jin Xiao-Dong; Yan Zheng
刊名HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION
出版日期2007-07-01
卷号31期号:7页码:655-659
关键词heavy-ion cancer therapy beam delivery system conformal irradiation beam shaping simulation
ISSN号0254-3052
英文摘要The passive beam delivery system in the superficially-placed tumor therapy terminal at Heavy Ion Researc h Facility in Lanzhou (HIRFL), which includes two orthogonal dipole magnets as scanning system, a motor-driven energy degrader as range-shifter, series of ridge filters as range modulator and a multileaf collimator, is introduced in detail. The capacities of its important components and the whole system have been verified experimentally. The tests of the ridge filter for extending Bragg peak and the range shifter for energy adjustment show both work well. To examine the passive beam delivery system, a beam shaping experiment were carried out, simulating a three-dimensional (3D) conformal irradiation to a tumor. The encouraging experimental result confirms that 3D layer-stacking conformal irradiation can be performed by means of the passive system. The validation of the beam delivery system establishes a substantial basis for upcoming clinical trial for superficially-placed tumors with heavy ions in the therapy terminal at HIRFL.
WOS研究方向Physics
语种英语
WOS记录号WOS:000247575200011
出版者SCIENCE PRESS
公开日期2010-10-29
源URL[http://ir.imp.cas.cn/handle/113462/5951]  
专题近代物理研究所_兰州重离子研究装置
近代物理研究所_近代物理研究所知识存储(2010之前)
通讯作者Dai Zhong-Ying
作者单位1.Grad Univ Chinese Acad Sci, Beijing 100049, Peoples R China
2.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
推荐引用方式
GB/T 7714
Dai Zhong-Ying,Li Qiang,Xiao Guo-Qing,et al. Capability verification of the beam delivery system in the superficially-placed tumor therapy terminal at HIRFL[J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,2007,31(7):655-659.
APA Dai Zhong-Ying,Li Qiang,Xiao Guo-Qing,Jin Xiao-Dong,&Yan Zheng.(2007).Capability verification of the beam delivery system in the superficially-placed tumor therapy terminal at HIRFL.HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,31(7),655-659.
MLA Dai Zhong-Ying,et al."Capability verification of the beam delivery system in the superficially-placed tumor therapy terminal at HIRFL".HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION 31.7(2007):655-659.

入库方式: OAI收割

来源:近代物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。