A numerical comparison between internal cooling and side cooling of the reflection mirror for Spatial and Spin (S-2) beam-line at SSRF

文献类型:期刊论文

作者Jin, LM; Zhu, WQ; Wang, Y; Wang, NX; Cao, JF; Xu, ZM
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2018
卷号902期号:-页码:190-196
关键词High Heat Load X-ray Mirror Synchrotron-radiation Undulator Beamline Performance Monochromator Fabrication Design Aps
ISSN号0168-9002
DOI10.1016/j.nima.2018.06.015
文献子类期刊论文
英文摘要

To select a more appropriate cooling method for a reflection mirror of Spatial and Spin (S-2) beam-line at SSRF (Shanghai Synchrotron Radiation Facility), both of the internal cooling method and side cooling method were proposed and compared at various selected energy points (the most important 50 eV, 80 eV, 100 eV and 867 eV) based on finite element analysis (FEA). For the internal cooling mode, several internal rectangular channels were drilled under the irradiation surface of mirror. For the side cooling mode, two pieces of perforated copper blocks in contact with two side surfaces of mirror were employed. Moreover, a series of side cooling modes with different tube lengths (145 mm, 200 mm, 225 mm, 248 mm and 250 mm) were analyzed. It was found that the side cooling mode with tube length of 248 mm indicated the best slope error results in all of the side cooling methods. By comparing the temperature, thermal stress distribution and slope error between the internal cooling mode and side cooling mode with tube length of 248 mm, it showed that all of the above mentioned indicators for both cooling modes were consistent with the design standards. However, the internal cooling mode presented the better results than this specific side cooling mode. In particular, by comparing some critical important influencing factors, such as the commercial cost, manufacturing process difficulty, manufacturing period and micro vibration issues, the side cooling mode with tube length of 248 mm presented better engineering operability, thus it was selected as the final cooling method for the reflection mirror of Spatial and Spin (S-2) beam-line at SSRF.

语种英语
源URL[http://ir.sinap.ac.cn/handle/331007/30826]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Jin, LM,Zhu, WQ,Wang, Y,et al. A numerical comparison between internal cooling and side cooling of the reflection mirror for Spatial and Spin (S-2) beam-line at SSRF[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2018,902(-):190-196.
APA Jin, LM,Zhu, WQ,Wang, Y,Wang, NX,Cao, JF,&Xu, ZM.(2018).A numerical comparison between internal cooling and side cooling of the reflection mirror for Spatial and Spin (S-2) beam-line at SSRF.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,902(-),190-196.
MLA Jin, LM,et al."A numerical comparison between internal cooling and side cooling of the reflection mirror for Spatial and Spin (S-2) beam-line at SSRF".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 902.-(2018):190-196.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。