Energy calibration of a CR-39 nuclear-track detector irradiated by charged particles
文献类型:期刊论文
作者 | Zhang, Y; Wang, HW; Ma, YG; Liu, LX; Cao, XG; Fan, GT; Zhang, GQ; Fang, DQ |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES
![]() |
出版日期 | 2019 |
卷号 | 30期号:6页码:— |
关键词 | BULK ETCH RATE |
ISSN号 | 1001-8042 |
DOI | 10.1007/s41365-019-0619-x |
文献子类 | 期刊论文 |
英文摘要 | Charged particle diagnosis is an important aspect of laser-plasma experiments conducted at super-intense laser facilities. In recent years, Columbia Resin #39 (CR-39) detectors have been widely employed for detecting charged particles in laser-plasma experiments. This is because the CR-39 polymer does not respond to electromagnetic pulses or X-rays. This study presents a method for calibrating the relationship between particle energy and track diameter in a CR-39 detector (TasTrak((R))) using 3-8MeV protons, 6-30MeV carbon ions, and 1-5MeV alpha particles. The particle tracks were compared under the manufacturer's recommended etching conditions of 6.25mol/l NaOH at 98 degrees C and under the widely adopted experimental conditions of 6.25mol/l NaOH at 70 degrees C. The results show that if the NaOH solution concentration is 6.25mol/l, then the temperature of 70 degrees C is more suitable for etching proton tracks than 98 degrees C and employing a temperature of 98 degrees C to etch alpha-particle and carbon-ion tracks can significantly reduce the etching time. Moreover, this result implies that C3+ ion or alpha-particle tracks can be distinguished from proton tracks with energy above 3MeV by controlling the etching time. This calibration method for the CR-39 detector can be applied to the diagnosis of reaction products in laser-plasma experiments. |
语种 | 英语 |
源URL | [http://ir.sinap.ac.cn/handle/331007/31598] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
作者单位 | 1.Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China; 2.ShanghaiTech Univ, Shanghai 201210, Peoples R China 3.Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China; 4.Univ Chinese Acad Sci, Beijing 100049, Peoples R China; |
推荐引用方式 GB/T 7714 | Zhang, Y,Wang, HW,Ma, YG,et al. Energy calibration of a CR-39 nuclear-track detector irradiated by charged particles[J]. NUCLEAR SCIENCE AND TECHNIQUES,2019,30(6):—. |
APA | Zhang, Y.,Wang, HW.,Ma, YG.,Liu, LX.,Cao, XG.,...&Fang, DQ.(2019).Energy calibration of a CR-39 nuclear-track detector irradiated by charged particles.NUCLEAR SCIENCE AND TECHNIQUES,30(6),—. |
MLA | Zhang, Y,et al."Energy calibration of a CR-39 nuclear-track detector irradiated by charged particles".NUCLEAR SCIENCE AND TECHNIQUES 30.6(2019):—. |
入库方式: OAI收割
来源:上海应用物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。