Investigation on Precooling Effects of 4 K Stirling-Type Pulse Tube Cryocoolers

文献类型:期刊论文

作者Cao Qiang; Li Zimu; Luan Mingkai; Sun Zheng; Tang Xiao; Li Peng; Jiang Zhenhua; Wei Li
刊名JOURNAL OF THERMAL SCIENCE
出版日期2019
卷号28期号:4页码:714-726
关键词stirling-type pulse tube cryocooler precooling effects liquid-helium temperatures
DOI10.1007/s11630-019-1168-7
英文摘要Stirling-type pulse tube cryocoolers (SPTCs) working at liquid-helium temperatures are appealing in space applications because of their promising advantages such as high reliability, compactness, etc. Worldwide efforts have been put in to develop SPTCs operating at liquid-helium temperatures especially with helium-4 as the working fluid. Staged structure is essential to reach such low temperatures. Generally, both the regenerator of the last section and the pulse tube together with the phase shifter are precooled by its upper stage or by external cold source to a low temperature of around 20 K. However, the precooling effects on the regenerator and the pulse tube are synthetic in previous studies, and their independent effects have not been studied clearly. In this manuscript, the precooling effects on the regenerator and on the pulse tube together with the phase shifter are tested independently on a unique-designed precooled SPTC. The tested precooling temperature is between 13.3 K and 22 K, and the no-load refrigeration temperature gets down to 3.6 K. Further analyses and numerical calculations have been carried out. It is found that the influence on the regenerator is remarkable, which is different from previous conclusions. It is also found that the precooling effects on the pulse tube are relatively weak because of the large pressure-induced enthalpy flow of a real gas working at the temperatures near to the critical point. Furthermore, the phase shifting capacity is analyzed with two cases and with both helium-4 and helium-3 as working fluids, and it keeps quite constant after optimizing the frequency and the precooling temperature for each case. The investigation on these independent effects will provide valid reference on the precooling mechanism study of SPTCs working down to liquid-helium temperatures.
WOS记录号WOS:473742000011
源URL[http://202.127.2.71:8080/handle/181331/12352]  
专题上海技术物理研究所_上海技物所
推荐引用方式
GB/T 7714
Cao Qiang,Li Zimu,Luan Mingkai,et al. Investigation on Precooling Effects of 4 K Stirling-Type Pulse Tube Cryocoolers[J]. JOURNAL OF THERMAL SCIENCE,2019,28(4):714-726.
APA Cao Qiang.,Li Zimu.,Luan Mingkai.,Sun Zheng.,Tang Xiao.,...&Wei Li.(2019).Investigation on Precooling Effects of 4 K Stirling-Type Pulse Tube Cryocoolers.JOURNAL OF THERMAL SCIENCE,28(4),714-726.
MLA Cao Qiang,et al."Investigation on Precooling Effects of 4 K Stirling-Type Pulse Tube Cryocoolers".JOURNAL OF THERMAL SCIENCE 28.4(2019):714-726.

入库方式: OAI收割

来源:上海技术物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。