英文摘要Implant failures still happen because of bacterial infections and inferior osteogenic properties. Graphene oxide (GO) could induce osteogenic differentiation as well as exhibit superior antibacterial activity which may provide an answer for this issue. In this work, GO films loaded with minocycline hydrochloride (MH) were fabricated on titanium implant surfaces, and the antibacterial activity and osteogenic properties were studied in the presence of S. aureus and rat bone mesenchymal stem cells (rBMSCs) in in vitro and in vivo environments, respectively. The results indicated that the MH loaded GO films on titanium surfaces (MH&GO@Ti) exhibited enhanced osteogenic activity in vitro with improved alkaline phosphatase (ALP) activity and enhanced osteogenic related gene expressions including ALP, collagen-I, osteocalcin, and osteopontin. The in vitro results of the co-culture of rBMSCs and S. aureus indicated that the rBMSCs grew well on the MH&GO@Ti sample with a higher coverage of cells and the bacteria were almost unobservable on the surface. In the in vivo experiments, the MH&GO@Ti exhibited excellent antibacterial and osteogenic activities in the presence of bacteria. No inflammatory cells for example neutrophils were found and superior bone-implant integration was obtained. This study offers a new proposal for the clinical application of drug-loaded graphene coating.
WOS研究方向Materials Science
语种英语
出版者ROYAL SOC CHEMISTRY
源URL[http://ir.sic.ac.cn/handle/331005/27051]  
专题中国科学院上海硅酸盐研究所
推荐引用方式
GB/T 7714
Qiu, Jiajun,Qian, Wenhao,Zhang, Jinkai,et al. Minocycline hydrochloride loaded graphene oxide enables enhanced osteogenic activity in the presence of Gram-positive bacteria, Staphylococcus aureus[J]. JOURNAL OF MATERIALS CHEMISTRY B,2019,7(22):3590.
APA Qiu, Jiajun,Qian, Wenhao,Zhang, Jinkai,Chen, Dafu,Yeung, Kelvin W. K.,&Liu, Xuanyong.(2019).Minocycline hydrochloride loaded graphene oxide enables enhanced osteogenic activity in the presence of Gram-positive bacteria, Staphylococcus aureus.JOURNAL OF MATERIALS CHEMISTRY B,7(22),3590.
MLA Qiu, Jiajun,et al."Minocycline hydrochloride loaded graphene oxide enables enhanced osteogenic activity in the presence of Gram-positive bacteria, Staphylococcus aureus".JOURNAL OF MATERIALS CHEMISTRY B 7.22(2019):3590.

入库方式: OAI收割

来源:上海硅酸盐研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。