中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Theoretical Model and Experiments of Resonance Frequency Shift by LC Tuning in Magnetoelectric Sensor

文献类型:期刊论文

作者Wang, Xiefu; Zhao, Jing; Xu, Bingbing; Di, Wenning; Lu, Li; Hu, Fei; Luo, Haosu; Gu, Haoshuang
刊名PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE
出版日期2019-06-01
卷号216期号:11
关键词equivalent magnetic noise LC tuning magnetoelectric sensor PMN-PT
ISSN号1862-6300
DOI10.1002/pssa.201800966
文献子类Article
英文摘要In this work, the authors present the resonance frequency shift of the magnetic sensor with Terfenol-D/PMN-PT heterostructure by LC tuning. A custom-built low noise voltage pre-amplifier is used to convert the weak signal induced by magnetic field into an output voltage. A practical noise model is established to theoretically analyze the variation of noise level of LC tuning magnetoelectric (ME) sensor. Both the theoretical analysis and experimental results indicate that LC tuning is an effective way to adjust the resonance frequency and reduce the equivalent magnetic noise (EMN). The resonance frequency of the LC tuning ME sensor can be shifted from 54.8 kHz to 24.8 kHz, with the maximum responsivity being 131 V/Oe@24.8 kHz. Furthermore, the EMN is as low as 0.22 pT/Hz(1/2)@24.8 kHz, which indicates a significant reduction from 0.54 pT/Hz(1/2) at the same frequency without LC tuning.
WOS研究方向Materials Science ; Physics
语种英语
出版者WILEY-V C H VERLAG GMBH
源URL[http://ir.sic.ac.cn/handle/331005/27074]  
专题中国科学院上海硅酸盐研究所
推荐引用方式
GB/T 7714
Wang, Xiefu,Zhao, Jing,Xu, Bingbing,et al. Theoretical Model and Experiments of Resonance Frequency Shift by LC Tuning in Magnetoelectric Sensor[J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE,2019,216(11).
APA Wang, Xiefu.,Zhao, Jing.,Xu, Bingbing.,Di, Wenning.,Lu, Li.,...&Gu, Haoshuang.(2019).Theoretical Model and Experiments of Resonance Frequency Shift by LC Tuning in Magnetoelectric Sensor.PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE,216(11).
MLA Wang, Xiefu,et al."Theoretical Model and Experiments of Resonance Frequency Shift by LC Tuning in Magnetoelectric Sensor".PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE 216.11(2019).

入库方式: OAI收割

来源:上海硅酸盐研究所

浏览0
下载0
收藏0
其他版本