中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Laser Doppler flowmetry for assessment of myocardial microperfusion in the beating rat heart

文献类型:期刊论文

作者Li, Xiao-Fen; Wang, Yi-Ping
刊名VASCULAR PHARMACOLOGY
出版日期2007-03
卷号46期号:3页码:207-214
关键词myocardial microperfusion laser Doppler flowmetry captopril nifedipine pituitrin
ISSN号1537-1891
DOI10.1016/j.vph.2006.10.003
文献子类Article
英文摘要Although laser Doppler flowmetry (LDF) is widely used for measuring microperfusion, it is rarely used to measure coronary microcirculation. The present in vivo study investigated the use of LDF to measure myocardial microperfusion in beating rat hearts. Ascending aortic flow and other hemodynamic parameters were simultaneously recorded. A needle probe with a holder was adhered to the epicardium of the left ventricular myocardium close to the left anterior descending coronary artery in an anaesthetized open-chest rat. Myocardial microperfusion was measured in response to bolus intravenous administration of both two representative vasodilators (captopril and nifedipine) and a vasoconstrictor (pituitrin). Myocardial microperfusion was found to be predominately diastolic, and in an opposing phase to the ascending aortic flow. Captopril (5 or 10 mg/kg) increased the initial myocardial microperfusion phase. Nifedipine at 75 mu g/kg caused a sustained myocardial microperfusion elevation with a peak increase of 7.1 +/- 1.1%, but this was not observed using 150 mu g/kg nifedipine. Both drugs caused an increase in the cardiac index. In contrast, myocardial microperfusion decreased (28.7 +/- 0.1% maximum decrease) in response to I IU/kg pituitrin. In conclusion, LDF provided a means of assessing myocardial microperfusion in beating rat hearts, and can be applied to evaluate the coronary microcirculation response to drugs. (c) 2006 Published by Elsevier Inc.
WOS关键词BLOOD-FLOW ; PORCINE HEART ; PERFUSION ; NIFEDIPINE ; MICROCIRCULATION ; HEMODYNAMICS ; MICROVESSELS ; INFARCTION ; VENTRICLE ; INFLOW
WOS研究方向Pharmacology & Pharmacy
语种英语
WOS记录号WOS:000244086600009
出版者ELSEVIER SCIENCE INC
源URL[http://119.78.100.183/handle/2S10ELR8/273318]  
专题药理学第一研究室
中科院受体结构与功能重点实验室
新药研究国家重点实验室
通讯作者Wang, Yi-Ping
作者单位1.Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
2.Shanghai Inst Biol Sci, Shanghai Inst Mat Med, State Key Lab Drug Res, Shanghai 201203, Peoples R China
推荐引用方式
GB/T 7714
Li, Xiao-Fen,Wang, Yi-Ping. Laser Doppler flowmetry for assessment of myocardial microperfusion in the beating rat heart[J]. VASCULAR PHARMACOLOGY,2007,46(3):207-214.
APA Li, Xiao-Fen,&Wang, Yi-Ping.(2007).Laser Doppler flowmetry for assessment of myocardial microperfusion in the beating rat heart.VASCULAR PHARMACOLOGY,46(3),207-214.
MLA Li, Xiao-Fen,et al."Laser Doppler flowmetry for assessment of myocardial microperfusion in the beating rat heart".VASCULAR PHARMACOLOGY 46.3(2007):207-214.

入库方式: OAI收割

来源:上海药物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。