Iron dextran peak molecular weight comparison determination in iron dextran injections
文献类型:期刊论文
作者 | Di ChenB; Chen Dongying![]() |
刊名 | Chinese Journal of New Drugs and Clinical Remedies
![]() |
出版日期 | 2005 |
卷号 | 24期号:6页码:438-440 |
关键词 | iron-dextran complex molecular weight chromatography, gel ehromatography high pressure liquid quality control |
ISSN号 | 1007-7669 |
其他题名 | 右旋糖酐铁注射液中右旋糖酐铁峰位相对分子质量的测定 |
文献子类 | Article |
英文摘要 | AIM; To establish a method for irondextran peak molecular weight determination in order to evaluate the quality of the two iron dextran injections. METHODS: High performance gel permeation chro-matography (HPGPC) was used to determine the peak molecular weight in the two injections. The TSK G4000SW gel column (7.5 mm x30.0 cm) and TSK-gel SW guard column (7.5 mm x 7. 5 cm) were uti-lized with 0. 1 % NaN3 as mobile phase taking known peak molecular weights of dextrans as the calibration standards and known peak molecular weights of iron dextrans as corrected standards. The flow rate was 1.0 mL- min"' with 30 °C as the temperature for the column and the reflective index detector. RE-SULTS; A method for peak molecular weight determi- nation of iron dextran was established. The peak mo-lecular weight for injection A was determined as 1.5 X 105 and for injection B as 4. 2 x 105. CONCLU-SION : A method for determination of iron dextran peak molecular weight was established and the values of peak molecular weight were varied greatly between the two injections suggesting different quality between them. |
WOS研究方向 | Pharmacology & Pharmacy (provided by Clarivate Analytics) |
语种 | 中文 |
CSCD记录号 | CSCD:2029491 |
源URL | [http://119.78.100.183/handle/2S10ELR8/268292] ![]() |
专题 | 药物质量控制与固体化学研究中心 |
作者单位 | Department of Pharmaceutical Analysis, Shanghai Institute of Materia Medica, Shanghai Institutes for Biobgical Sciences, Chinese Academy of Sciences, Shanghai 201203, China. |
推荐引用方式 GB/T 7714 | Di ChenB,Chen Dongying,Gao Jin. Iron dextran peak molecular weight comparison determination in iron dextran injections[J]. Chinese Journal of New Drugs and Clinical Remedies,2005,24(6):438-440. |
APA | Di ChenB,Chen Dongying,&Gao Jin.(2005).Iron dextran peak molecular weight comparison determination in iron dextran injections.Chinese Journal of New Drugs and Clinical Remedies,24(6),438-440. |
MLA | Di ChenB,et al."Iron dextran peak molecular weight comparison determination in iron dextran injections".Chinese Journal of New Drugs and Clinical Remedies 24.6(2005):438-440. |
入库方式: OAI收割
来源:上海药物研究所