中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Detecting metastasis of gastric carcinoma using high-resolution micro-CT system: In vivo small animal study

文献类型:会议论文

作者Liu, Junting5; Tian, Jie4,5; Liang, Jimin5; Li, Xiangsi5; Yang, Xiang1; Chen, Xiaofeng1; Chen, Yi2; Zhou, Yuanfeng2; Wang, Xiaorui3
出版日期2011
卷号7965
DOI10.1117/12.878410
英文摘要Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2×106BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.
会议录Progress in Biomedical Optics and Imaging - Proceedings of SPIE
会议录出版者SPIE
文献子类Proceedings Paper
语种英语
源URL[http://119.78.100.183/handle/2S10ELR8/266856]  
专题药理学第一研究室
通讯作者Tian, Jie
作者单位1.Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd., Guangzhou 510663, China;
2.Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China;
3.School of Technical Physics, Xidian University, Xi'an 710071, China
4.Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China;
5.School of Life Sciences and Technology, Xidian University, Xi'an 710071, China;
推荐引用方式
GB/T 7714
Liu, Junting,Tian, Jie,Liang, Jimin,et al. Detecting metastasis of gastric carcinoma using high-resolution micro-CT system: In vivo small animal study[C]. 见:.

入库方式: OAI收割

来源:上海药物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。