中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A comparison report of three advanced methods for drug-cyclodextrin interaction measurements

文献类型:期刊论文

作者Singh, Vikramjeet3; He, Yaping3; Wang, Caifen1,3; Xu, Jianghui3; Xu, Xiaonan3,4; Li, Haiyan3; Singh, Parbeen3; York, Peter2,3; Sun, Lixin4; Zhang, Jiwen1,3
刊名JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
出版日期2017-02-05
卷号134页码:252-258
关键词Drug-cyclodextrins interactions High performance affinity chromatography Surface plasmon resonance Surface plasmon resonance imaging Kinetic constants Sparingly soluble drugs
ISSN号0731-7085
DOI10.1016/j.jpba.2016.11.037
文献子类Article
英文摘要Three advanced methods, high performance affinity chromatography (HPAC), surface plasmon resonance (SPR) and surface plasmon resonance imaging (SPRi) were compared and evaluated for determining the drug-cyclodextrin (CD) interactions herein. In total, 18 sparingly soluble drugs were selected for this comparative study. The three methods share a unique connection in the working principles and strategies. The same strategies of CD fixation onto solid phase were used in HPAC and SPR for the measurements, whereas, the SPR and SPRi share identical working principles. However, whilst these relationships are evident, no strong correlation was found between kinetic constants obtained from the three methods: Four drugs, namely, prednisolone, pseudolaric acid B, diazepam and gramisetron failed to show any response on SPR, whereas, the kinetics parameters from SPRi and HPAC were successfully measured. From a comparative review of all the kinetic data, random results without any trends were observed (ka, kd and K-A) regardless of the relationships between the three methods: It is apparent that the measurement conditions (volume, flow rate, buffers), non-specific adsorption and experimental procedures had a strong impact on the generated data. The relative advantages and limitations of each method are critically presented on the basis of generated data. This comparative study provides a basis to further upgrade these techniques for confident measurement of drug-CDs interactions. (C) 2016 Elsevier B.V. All rights reserved.
WOS关键词SURFACE-PLASMON RESONANCE ; FLUORESCENCE CORRELATION SPECTROSCOPY ; BETA-CYCLODEXTRIN ; BIOLOGICAL-MEMBRANES ; BIACORE(R) SYSTEM ; COMPLEXES ; DYNAMICS ; BINDING
资助项目National Natural Science Foundation of China[81430087] ; National Natural Science Foundation of China[81573392] ; National Science and Technology Major Project[2013ZX09402103]
WOS研究方向Chemistry ; Pharmacology & Pharmacy
语种英语
WOS记录号WOS:000392909900032
出版者ELSEVIER SCIENCE BV
源URL[http://119.78.100.183/handle/2S10ELR8/275635]  
专题药物制剂研究中心
通讯作者Sun, Lixin; Zhang, Jiwen
作者单位1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
2.Univ Bradford, Inst Pharmaceut Innovat, Bradford BD7 1DP, W Yorkshire, England;
3.Chinese Acad Sci, Shanghai Inst Mat Med, Ctr Drug Delivery Syst, 501 Haike Rd, Shanghai 201203, Peoples R China;
4.Shenyang Pharmaceut Univ, Sch Pharm, Dept Pharmaceut Anal, 103 Wenhua Rd, Shenyang 110016, Peoples R China;
推荐引用方式
GB/T 7714
Singh, Vikramjeet,He, Yaping,Wang, Caifen,et al. A comparison report of three advanced methods for drug-cyclodextrin interaction measurements[J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,2017,134:252-258.
APA Singh, Vikramjeet.,He, Yaping.,Wang, Caifen.,Xu, Jianghui.,Xu, Xiaonan.,...&Zhang, Jiwen.(2017).A comparison report of three advanced methods for drug-cyclodextrin interaction measurements.JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,134,252-258.
MLA Singh, Vikramjeet,et al."A comparison report of three advanced methods for drug-cyclodextrin interaction measurements".JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS 134(2017):252-258.

入库方式: OAI收割

来源:上海药物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。