Pharmacokinetics of ganoderic acid D and its main metabolite by liquid chromatography-tandem mass spectrometry
文献类型:期刊论文
作者 | Cheng, Chun-Ru1,2; Yang, Min1; Guan, Shu-Hong1![]() ![]() |
刊名 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
出版日期 | 2013-07-01 |
卷号 | 930页码:1-6 |
关键词 | Ganoderic acid D Ganoderic acid B LC/MS/MS Nanoparticle Pharmacokinetics Triterpenoid |
ISSN号 | 1570-0232 |
DOI | 10.1016/j.jchromb.2013.04.015 |
文献子类 | Article |
英文摘要 | The present study aims to investigate the pharmacokinetics of ganoderic acid D (GD), a representative active triterpenoid from Ganoderrna lucidum. A sensitive and selective liquid chromatography-tandem mass spectrometry method was developed for the simultaneous determination of the concentrations of GD and its main metabolite (ganoderic acid B) in rat plasma. Following protein precipitation, the analytes were separated on a reversed-phase C18 column. Acetonitrile-water-acetic acid (40:60:0.01) was used at a flow-rate of 0.2 ml/min. A triple quadrupole mass spectrometer equipped with an electro-spray ionization source was used as the detector and was operated in the negative ion mode. Multiple reaction monitoring using the characteristic transitions was performed to quantify the analytes. The method had a lower limit of quantification of 8.19 ng/ml for GD, and 8.59 ng/ml for ganoderic acid B (GB). The calibration curves were demonstrated to be linear over the concentration range of 8.19-4096 ng/ml and 8.59-2149 ng/ml, respectively. Variations within- and between-batch were less than 6.4% and 4.6%, respectively. The extraction recovery rates ranged from 98.8 to 105.2% and 100.7 to 113.6%, respectively. The validated method was successfully applied to the quantification of GD and GB concentrations in rat plasma after oral administration (or intravenous administration) of GD preparations at a dose of 15 mg/kg. The data showed that the absolute bioavailability increased from 22% to 70% after the GD suspension was changed to GD loaded solid lipid nanoparticles. In the meantime, the C-max increased from 107.2 to 1555.6 ng/ml; the t(max) changed from 2.0 h to 0.3 h. These results are very helpful in the further studies. (C) 2013 Elsevier B.V. All rights reserved. |
WOS关键词 | LUCIDUM ; TRITERPENOIDS |
资助项目 | National Natural Science Foundation of China[81001630] ; Natural Science Foundation of Shanghai[10ZR1436400] ; Chinese Academy of Sciences[KSCX2-YW-R-166] ; Twelfth Five-Year National Science & Technology Support Program[2012BAI29B06] ; Major Project of Zigong Municipal and Technology Bureau[11GC016] ; Sichuan University of Science Engineering[2012RC17] ; Sichuan University of Science Engineering[2012RC15] |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
语种 | 英语 |
WOS记录号 | WOS:000320744800001 |
出版者 | ELSEVIER SCIENCE BV |
源URL | [http://119.78.100.183/handle/2S10ELR8/277559] ![]() |
专题 | 上海中药现代化研究中心 |
通讯作者 | Yang, Min |
作者单位 | 1.Chinese Acad Sci, Shanghai Inst Biol Sci, Shanghai Inst Mat Med,Natl Engn Lab TCM Standardi, Shanghai Res Ctr Modernizat Tradit Chinese Med, Shanghai 201203, Peoples R China; 2.Sichuan Univ Sci & Engn, Sch Chem & Pharmaceut Engn, Zigong 643000, Sichuan, Peoples R China; 3.Tianjin Med Univ, Coll Pharm, Tianjin Key Lab Technol Enabling Dev Clin Therape, Tianjin 300070, Peoples R China |
推荐引用方式 GB/T 7714 | Cheng, Chun-Ru,Yang, Min,Guan, Shu-Hong,et al. Pharmacokinetics of ganoderic acid D and its main metabolite by liquid chromatography-tandem mass spectrometry[J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,2013,930:1-6. |
APA | Cheng, Chun-Ru.,Yang, Min.,Guan, Shu-Hong.,Wu, Xiao-Hui.,Pang, Xiao-Yan.,...&Guo, De-An.(2013).Pharmacokinetics of ganoderic acid D and its main metabolite by liquid chromatography-tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,930,1-6. |
MLA | Cheng, Chun-Ru,et al."Pharmacokinetics of ganoderic acid D and its main metabolite by liquid chromatography-tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 930(2013):1-6. |
入库方式: OAI收割
来源:上海药物研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。