中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
An all-solid-state potentiometric microelectrode for detection of copper in coastal sediment pore water

文献类型:期刊论文

作者Zhao, Guangtao; Liang, Rongning; Wang, Feifan; Ding, Jiawang; Qin, Wei
刊名SENSORS AND ACTUATORS B-CHEMICAL
出版日期2019-01-15
卷号279页码:369-373
关键词Ion-selective microelectrodes Potentiometry Pore water Copper
ISSN号0925-4005
DOI10.1016/j.snb.2018.09.125
产权排序[Zhao, Guangtao ; Liang, Rongning ; Wang, Feifan ; Ding, Jiawang ; Qin, Wei] Chinese Acad Sci, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC, Shandong Prov Key Lab Coastal Environm Proc,YICCA, Yantai 264003, Shandong, Peoples R China ; [Zhao, Guangtao ; Liang, Rongning ; Wang, Feifan ; Ding, Jiawang ; Qin, Wei] Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao, Peoples R China ; [Zhao, Guangtao] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
文献子类Article
英文摘要Potentiometric microelectrodes are regarded as promising probes for ion sensing when only limited sample volumes are available. In this work, an all-solid-state ion-selective microelectrode (IS mu E) has been developed by coating ionophore-based ion-selective membrane on a poly(3,4-ethylenedioxythiophene)-poly(sodium 4-styrenesulfonate) modified gold wire with a diameter of 14 mu m for detection of copper. Under the optimized conditions, the proposed all-solid-state Cu2+-IS mu E shows a Nernst response toward Cu2+ in 0.5 M NaCl in the range from 2.5 x 10(-7) to 2.5 x 10(-4) M with a detection limit of 4.0 x 10(-8) M. Additionally, the Cu2+-IS mu E has been used for monitoring the vertical distribution profile of Cu2+ in coastal sediment pore water with a small volume (e.g., 300 mu L). The results agree well with those obtained by anodic stripping voltammetry, which indicates that the proposed potentiometric technique based on the all-solid-state IS mu E is promising for detection of Cu2+ in coastal sediment pore water. The method for the preparation of the IS mu E can be extended to detect other heavy metal ions in sediments by using different ion-selective membranes.
WOS关键词ION-SELECTIVE ELECTRODES ; SCANNING ELECTROCHEMICAL MICROSCOPY ; CARBON NANOTUBES ; CADMIUM FLUXES ; TRACE LEVELS ; CONTACT ; SAMPLES ; TRANSDUCERS ; MEMBRANES ; CORROSION
WOS研究方向Chemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation
语种英语
WOS记录号WOS:000449373800046
资助机构Instrument Developing Project of the Chinese Academy of Sciences [Y728021021] ; National Natural Science Foundation of China [21677172, 21575158] ; National Key Research and Development Program of China [2016YFC1400700] ; Taishan Scholar Program of Shandong Province [TS20081159] ; Youth Innovation Promotion Association of CAS [2014190]
源URL[http://ir.yic.ac.cn/handle/133337/24622]  
专题烟台海岸带研究所_近岸生态与环境实验室
烟台海岸带研究所_中科院海岸带环境过程与生态修复重点实验室
作者单位1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
2.Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao, Peoples R China;
3.Chinese Acad Sci, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC, Shandong Prov Key Lab Coastal Environm Proc,YICCA, Yantai 264003, Shandong, Peoples R China;
推荐引用方式
GB/T 7714
Zhao, Guangtao,Liang, Rongning,Wang, Feifan,et al. An all-solid-state potentiometric microelectrode for detection of copper in coastal sediment pore water[J]. SENSORS AND ACTUATORS B-CHEMICAL,2019,279:369-373.
APA Zhao, Guangtao,Liang, Rongning,Wang, Feifan,Ding, Jiawang,&Qin, Wei.(2019).An all-solid-state potentiometric microelectrode for detection of copper in coastal sediment pore water.SENSORS AND ACTUATORS B-CHEMICAL,279,369-373.
MLA Zhao, Guangtao,et al."An all-solid-state potentiometric microelectrode for detection of copper in coastal sediment pore water".SENSORS AND ACTUATORS B-CHEMICAL 279(2019):369-373.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。