作者 | Xiangyang Li1 ; Jianjun Ding1; Yanping Liu2; Xingyou Tian1
|
刊名 | IUCrJ
 |
出版日期 | 2019-09
|
关键词 | small-angle X-ray scattering
evanescent waves
lamellar thickness
spherulite
|
DOI | https://doi.org/10.1107/S2052252519011035
|
产权排序 | 1
|
英文摘要 | As is well known, polymers commonly form lamellar crystals, and these
assemble further into lamellar stacks and spherulites during quiescent crystallization. Fifty years ago, Vonk and Kortleve constructed the classical small-angle X-ray scattering theory (SAXS) for a lamellar system, in which it was assumed that the lamellar stack had an infinite lateral size [Vonk & Kortleve (1967),Kolloid Z. Z. Polym. 220, 19–24]. Under this assumption, only crystal planes satisfying the Bragg condition can form strong scattering, and the scattering from the lamellar stack arises from the difference between the scattering
intensities in the amorphous and crystalline layers, induced by the incident X-ray beam. This assumption is now deemed unreasonable. In a real polymer spherulite, the lamellar crystal commonly has dimensions of only a few hundred nanometres. At such a limited lateral size, lamellar stacks in a broad orientation have similar scattering, so interference between these lamellar stacks must be considered. Scattering from lamellar stacks parallel to the incident X-ray beam
also needs to be considered when total reflection occurs. In this study, various scattering contributions from lamellar stacks in a spherulite are determined. It is found that, for a limited lateral size, the scattering induced by the incident X-ray beam is not the main origin of SAXS. It forms double peaks, which are not observed in real scattering because of destructive interference between the lamellar stacks. The scattering induced by the evanescent wave is the main
origin. It can form a similar interference pattern to that observed in a real SAXS measurement: a Guinier region in the small-q range, a signal region in the intermediate-q range and a Porod region in the high-q range. It is estimated that, to avoid destructive interference, the lateral size needs to be greater than 11 mm,which cannot be satisfied in a real lamellar system. Therefore, SAXS in a real
polymer system arises largely from the scattering induced by the evanescent wave. Evidence for the existence of the evanescent wave was identified in the scattering of isotactic polypropylene. This study corrects a long-term misunderstanding of SAXS in a polymer lamellar system.
|
学科主题 | 物理学
|
URL标识 | 查看原文
|
语种 | 英语
|
WOS记录号 | WOS:000484171300021
|
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/42736]  |
专题 | 中科院固体物理研究所_专题未命名
|
通讯作者 | Xiangyang Li |
作者单位 | 1.Hefei Institutes of Physical Science 2.Zhengzhou University
|
推荐引用方式 GB/T 7714 |
Xiangyang Li,Jianjun Ding,Yanping Liu,et al. A new small-angle X-ray scattering model for polymer spherulites with a limited lateral size of the lamellar crystals[J]. IUCrJ,2019.
|
APA |
Xiangyang Li,Jianjun Ding,Yanping Liu,&Xingyou Tian.(2019).A new small-angle X-ray scattering model for polymer spherulites with a limited lateral size of the lamellar crystals.IUCrJ.
|
MLA |
Xiangyang Li,et al."A new small-angle X-ray scattering model for polymer spherulites with a limited lateral size of the lamellar crystals".IUCrJ (2019).
|