Antenna Array Initial Condition Calibration Method for Integrated Optical Phased Array
文献类型:期刊论文
作者 | Zhang, Qi-Hao1,2; Zhang, Ling-Xuan2; Li, Zhong-Yu2; Wu, Wei1,2; Wang, Guo-Xi1,2![]() ![]() |
刊名 | Guangzi Xuebao/Acta Photonica Sinica
![]() |
出版日期 | 2020-07-01 |
卷号 | 49期号:7 |
关键词 | Integrated chips Numerical calculation Phased array Antenna patterns(antenna) Phase calibration Error analysis |
ISSN号 | 10044213 |
DOI | 10.3788/gzxb20204907.0726001 |
其他题名 | 用于光学相控阵天线的初始校准算法 |
产权排序 | 1 |
英文摘要 | To solve the problem that the phase error of the optical phased array is difficult to calibrate, rotating element electric field vector calibration method is modified. Comparing with the traditional method, the new method modifies the algorithm and corrects the phase immediately after measuring the phase error of one unit, then measures and corrects the phase of the next unit. Possible π phase error in traditional method is avoided when large initial phase distribution and finite optical power measurement accuracy present. The simulation results show that the main lobe intensity calibrated with the original method reaches at most 70.8% of the ideal value on average, and the standard deviation is at least 19.1%. While after calibration with the modified method the main lobe intensity reaches at least 87.6% of the ideal value on average, the maximum standard deviation is 7.3%. The modified method produces statistically more accurate and predictable calibration result. A 9×9 optical phased array chip is manufactured. The initial grating lobe suppression ratio ofthe chip is 2.12 dB. Calibrated with this modified method the ratio reaches 4.68 dB. The effectiveness and practical application value of this method are proved. © 2020, Science Press. All right reserved. |
语种 | 英语 |
出版者 | Chinese Optical Society |
源URL | [http://ir.opt.ac.cn/handle/181661/93644] ![]() |
专题 | 西安光学精密机械研究所_瞬态光学技术国家重点实验室 |
作者单位 | 1.University of Chinese Academy of Sciences, Beijing; 100049, China 2.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Science, Xi'an; 710119, China; |
推荐引用方式 GB/T 7714 | Zhang, Qi-Hao,Zhang, Ling-Xuan,Li, Zhong-Yu,et al. Antenna Array Initial Condition Calibration Method for Integrated Optical Phased Array[J]. Guangzi Xuebao/Acta Photonica Sinica,2020,49(7). |
APA | Zhang, Qi-Hao.,Zhang, Ling-Xuan.,Li, Zhong-Yu.,Wu, Wei.,Wang, Guo-Xi.,...&Zhang, Wen-Fu.(2020).Antenna Array Initial Condition Calibration Method for Integrated Optical Phased Array.Guangzi Xuebao/Acta Photonica Sinica,49(7). |
MLA | Zhang, Qi-Hao,et al."Antenna Array Initial Condition Calibration Method for Integrated Optical Phased Array".Guangzi Xuebao/Acta Photonica Sinica 49.7(2020). |