A Fast-Response Calorimeter with Dynamic Corrections for Transient Heat Transfer Measurements

文献类型:期刊论文

作者Zhang SZ(张仕忠)2; Wang Q(汪球)1,2; Li JP(李进平)1,2; Zhang XY(张晓源)2; Chen H(陈宏)1,2
刊名APPLIED SCIENCES-BASEL
出版日期2020-09-01
卷号10期号:17页码:22
关键词calorimeter shock tunnel heat transfer measurement hypersonic
DOI10.3390/app10176143
通讯作者Wang, Qiu(wangqiu@imech.ac.cn) ; Zhang, Xiaoyuan(zhangxiaoyuan@imech.ac.cn)
英文摘要Robust fast-response transient calorimeters with novel calorimeter elements have attracted the attention of researchers as new synthetic materials have been developed. This sensor uses diamonds as the calorimeter element, and a platinum film resistance is sputtered on the back to measure the temperature. The surface heat flux is obtained based on the calorimetric principle. The sensor has the advantages of high sensitivity and not being prone to erosion. However, non-ideal conditions, such as heat dissipation from the calorimeter element to the surroundings, can lead to measurement deviation and result in challenges for sensor miniaturization. In this study, a novel transient calorimeter (NTC) with two different sizes was developed using air or epoxy as the back-filling material. Numerical simulations were conducted to explain the complex heat exchange between the calorimeter element and its surroundings, which showed that it deviated from the assumption of an ideal calorimeter sensor. Accordingly, a dynamic correction method was proposed to compensate for the energy loss from the backside of the calorimeter element. The numerical results showed that the dynamic correction method significantly improved the measurement deviation, and the relative error was within 2.3% if the test time was smaller than 12 ms in the simulated cases. Detonation shock tunnel experiments confirmed the results of the dynamic correction method and demonstrated a practical method to obtain the dynamic correction coefficient. The accuracy and feasibility of the dynamic correction method were verified in a single detonation shock tunnel and under shock tube conditions. The NTC calorimeter exhibited good repeatability in all experiments.
分类号二类
WOS关键词SURFACE JUNCTION THERMOCOUPLES ; THERMAL PRODUCT
资助项目National Natural Science Foundation of China[11402275] ; National Natural Science Foundation of China[11902328]
WOS研究方向Chemistry ; Engineering ; Materials Science ; Physics
语种英语
WOS记录号WOS:000569598300001
资助机构National Natural Science Foundation of China
其他责任者Wang, Qiu ; Zhang, Xiaoyuan
源URL[http://dspace.imech.ac.cn/handle/311007/85249]  
专题力学研究所_高温气体动力学国家重点实验室
作者单位1.Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
2.Chinese Acad Sci, Inst Mech, State Key Lab High Temp Gas Dynam, Beijing 100190, Peoples R China;
推荐引用方式
GB/T 7714
Zhang SZ,Wang Q,Li JP,et al. A Fast-Response Calorimeter with Dynamic Corrections for Transient Heat Transfer Measurements[J]. APPLIED SCIENCES-BASEL,2020,10(17):22.
APA 张仕忠,汪球,李进平,张晓源,&陈宏.(2020).A Fast-Response Calorimeter with Dynamic Corrections for Transient Heat Transfer Measurements.APPLIED SCIENCES-BASEL,10(17),22.
MLA 张仕忠,et al."A Fast-Response Calorimeter with Dynamic Corrections for Transient Heat Transfer Measurements".APPLIED SCIENCES-BASEL 10.17(2020):22.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。