英文摘要 | The surface reflectance is one of the most critical parameters during a field vicarious calibration. Traditional methods to measure the surface reflectance require personnel at the test site. A ground-viewing radiometer is built to measure the surface reflectance automatically. The radiometer has eight channels in the wavelength range from 400 nm to 1550 nm. The optical system is temperature controlled. A feedback resistor calculation method is introduced that is used to obtain a reasonable signal. Solar radiation-based calibration and two other laboratory methods are used to obtain the absolute calibration coefficients of the radiometer. The average difference in top-of atmosphere spectral radiance is less than 5% between the nine bands of S-NPP and automated vicarious calibration for eight months. The difference of apparent radiance between the results of OLI and automated vicarious calibration is mostly within 5%, therefore, the radiometer works effectively. |
资助项目 | National Key R&D Programme of China[2018YFB0504905] ; Natural National Science Foundation of China (NSFC)[41705013] |
WOS研究方向 | Optics |
语种 | 英语 |
WOS记录号 | WOS:000562611100001 |
出版者 | TAYLOR & FRANCIS LTD |
资助机构 | National Key R&D Programme of China ; Natural National Science Foundation of China (NSFC) |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/70484] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Huang, Xionghao |
作者单位 | 1.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Opt Calibrat & Characterizat, Hefei 230031, Peoples R China 2.Univ Sci & Technol China, Hefei 230026, Peoples R China |
推荐引用方式 GB/T 7714 | Huang, Xionghao,Li, Xin,Zheng, Xiaobing,et al. Design principles and radiometric calibration of a ground-viewing radiometer for automated vicarious calibration[J]. JOURNAL OF MODERN OPTICS,2020,67. |
APA | Huang, Xionghao,Li, Xin,Zheng, Xiaobing,Wei, Wei,&Xu, Haidon.(2020).Design principles and radiometric calibration of a ground-viewing radiometer for automated vicarious calibration.JOURNAL OF MODERN OPTICS,67. |
MLA | Huang, Xionghao,et al."Design principles and radiometric calibration of a ground-viewing radiometer for automated vicarious calibration".JOURNAL OF MODERN OPTICS 67(2020). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。