Design and characteristics of a low-frequency magnetic probe for magnetic profile measurements at Wendelstein 7-X
文献类型:期刊论文
作者 | Knieps, A.1; Liang, Y.1,3,4; Drews, P.1; Endler, M.2; Grulke, O.2; Huang, Z.1,4; Killer, C.2; Liu, S.1,3; Nicolai, D.1; Rahbarnia, K.2 |
刊名 | REVIEW OF SCIENTIFIC INSTRUMENTS
![]() |
出版日期 | 2020-07-01 |
卷号 | 91 |
ISSN号 | 0034-6748 |
DOI | 10.1063/5.0002193 |
通讯作者 | Knieps, A.(a.knieps@fz-juelich.de) |
英文摘要 | Equilibrium analysis in fusion devices usually relies on plasma pressure profiles and magnetic measurements outside the plasma. The kinetic profiles can give indirect information about the equilibrium magnetic field, while the stationary magnetic diagnostics cannot resolve current distributions on a smaller scale. This work presents a reciprocating magnetic probe, designed to provide direct plasma response measurements of the magnetic field in the scrape-off layer of Wendelstein 7-X. Hardware design and frequency characteristics are discussed, and a post-processing technique for extending the lower frequency cutoff of the integration scheme is presented. |
WOS关键词 | DIVERTOR ; W7-X ; DIAGNOSTICS ; MDSPLUS ; SYSTEM |
资助项目 | Euratom Research and Training Programme[633053] ; National Natural Science Foundation of China[51828101] |
WOS研究方向 | Instruments & Instrumentation ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000554065000002 |
出版者 | AMER INST PHYSICS |
资助机构 | Euratom Research and Training Programme ; National Natural Science Foundation of China |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/70877] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Knieps, A. |
作者单位 | 1.Forschungszentrum Julich, Inst Energie & Klimaforsch Plasmaphys, Partner Trilateral Euregio Cluster TEC, D-52425 Julich, Germany 2.Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany 3.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China 4.Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Int Joint Res Boratoryof Magnet Confinement Fus &, Wuhan 430074, Peoples R China |
推荐引用方式 GB/T 7714 | Knieps, A.,Liang, Y.,Drews, P.,et al. Design and characteristics of a low-frequency magnetic probe for magnetic profile measurements at Wendelstein 7-X[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2020,91. |
APA | Knieps, A..,Liang, Y..,Drews, P..,Endler, M..,Grulke, O..,...&Satheeswaran, G..(2020).Design and characteristics of a low-frequency magnetic probe for magnetic profile measurements at Wendelstein 7-X.REVIEW OF SCIENTIFIC INSTRUMENTS,91. |
MLA | Knieps, A.,et al."Design and characteristics of a low-frequency magnetic probe for magnetic profile measurements at Wendelstein 7-X".REVIEW OF SCIENTIFIC INSTRUMENTS 91(2020). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。