Numerical analysis of thermal stratification dependence on mass flow rate of coolant during LOFA in pools of CLEAR-S

文献类型:期刊论文

作者Ali, Muhammad Younas1,2; Jin, Ming1; Zhang, Guangyu1; Wang, Lei1
刊名PROGRESS IN NUCLEAR ENERGY
出版日期2020-07-01
卷号125
关键词LBE CLEAR-S Thermal stratification CFD LOFA
ISSN号0149-1970
DOI10.1016/j.pnucene.2020.103380
通讯作者Jin, Ming(ming.jin@fds.org.cn)
英文摘要During the start-up or operation of pool type lead cooled fast reactor, it is probable that loss of flow transient appears from forced circulation or mass flow rate less than that during forced circulation, due to any flow blockage, station blackout or pump malfunction. In this type of scenario temperature distribution and movement of thermal stratification layer will be different from that during loss of flow transient from forced circulation. Computational fluid dynamics (CFD) transient analysis of three-dimensional model of CLEAR-S was performed in this research with the use of commercial code FLUENT to analyze the influence of initial coolant mass flow rate on flow and coolant temperature profile in different constituents of engineering validation facility (CLEAR-S) during loss of flow transient. Firstly, steady state was simulated at mass flow rate equal to 100%, 50% and 25% of the rated mass flow rate respectively. Than loss of flow transient was simulated after started from the steady state of 100%, 50% and 25% of the rated mass flow rate as t = 0 sec respectively to understand the movement and temperature distribution of thermal stratification within the pools of CLEAR-S. Results showed that after loss of flow transient from 100%, 50% and 25% mass flow rate, LBE in the hot pool was distributed into five to six layers of different temperatures and temperature of LBE on both sides of stratification layer increased with the decrease of initial mass flow rate. As time progressed hot pool stratification layer proceeded upward and width of top most layer of LBE with high temperature reduced which ultimately vanished after giving birth to a new layer at hot pool bottom. Stratification initiated from DHR outlet in the cold pool after loss of flow transient from 100% mass flow rate. Thermal stratification was observed to be started at heat exchanger (HX) outlet during loss of flow transient initiated form 50% and 25% of mass flow rate. Temperature of LBE on both sides of stratification layer increased with the decrease of initial cold pool mass flow rate of CLEAR-S. With the proceeding of time Stratification layer raised upward and top most layer vanished.
WOS关键词CONCEPTUAL DESIGN ; DEVELOPMENT STRATEGY ; UPPER PLENUM ; PROGRESS ; REACTOR
资助项目Strategic Priority Research Program of Chinese Academy of Sciences[XDA22010504] ; Key Research Program of the Chinese Academy of Sciences[ZDRW-KT-2019-1-0202] ; Key Research Program of the 13th five-year plan of Hefei institute of Physical Science, Chinese Academy of Sciences[KP-2017-36]
WOS研究方向Nuclear Science & Technology
语种英语
WOS记录号WOS:000539411400017
出版者PERGAMON-ELSEVIER SCIENCE LTD
资助机构Strategic Priority Research Program of Chinese Academy of Sciences ; Key Research Program of the Chinese Academy of Sciences ; Key Research Program of the 13th five-year plan of Hefei institute of Physical Science, Chinese Academy of Sciences
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/102995]  
专题中国科学院合肥物质科学研究院
通讯作者Jin, Ming
作者单位1.Chinese Acad Sci, Inst Nucl Energy Safety Technol, Key Lab Neutron & Radiat Safety, Hefei 230031, Anhui, Peoples R China
2.Univ Sci & Technol China, Hefei 230027, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Ali, Muhammad Younas,Jin, Ming,Zhang, Guangyu,et al. Numerical analysis of thermal stratification dependence on mass flow rate of coolant during LOFA in pools of CLEAR-S[J]. PROGRESS IN NUCLEAR ENERGY,2020,125.
APA Ali, Muhammad Younas,Jin, Ming,Zhang, Guangyu,&Wang, Lei.(2020).Numerical analysis of thermal stratification dependence on mass flow rate of coolant during LOFA in pools of CLEAR-S.PROGRESS IN NUCLEAR ENERGY,125.
MLA Ali, Muhammad Younas,et al."Numerical analysis of thermal stratification dependence on mass flow rate of coolant during LOFA in pools of CLEAR-S".PROGRESS IN NUCLEAR ENERGY 125(2020).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。