Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera

文献类型:期刊论文

作者Huang, Chan2,3,4; Xiang, Guangfeng2,3,4; Chang, Yuyang2,3,4; Han, Lin2,4; Zhang, Miaomiao1; Li, Shuang2,4; Tu, Bihai2,4; Meng, Binghuan2,4; Hong, Jin2,4
刊名OPTICS EXPRESS
出版日期2020-04-27
卷号28
ISSN号1094-4087
DOI10.1364/OE.391078
通讯作者Meng, Binghuan(bhmeng@aiofm.en)
英文摘要The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth's reflectance. It acquires the two-dimensional image of the earth with a large field of view (118.74 degrees) and a high spatial resolution (3.3 km) in 8 spectral bands. The first DPC was successfully launched onboard the GaoFen-5 satellite in May 2018, subject to the Chinese high-resolution earth observation program. In this paper, a set of systematic and complete pre-flight calibrations of the DPC are proposed to ensure the effective characterization for in-flight calibration, so as to ensure the accuracy of DPC measured radiation polarization data and the reliability of inversion results. Since the geometric calibration method of the DPC has been presented in an early companion paper [Appl. Opt. 59 226 (2020)], this paper will not introduce it in detail. Instead, the geometric calibration results of each spectral band together with a discussion on the origin of differences between spectral bands are analyzed, and the error analysis of the method is conducted. The results of the DPC geometric calibration is that the residuals of all spectral bands are less than 0.1 pixel. For radiometric calibration, the radiometric models of non-polarized bands and polarized bands are derived in detail, respectively, and the specific calibration methods with error analysis, equipment, and main results with their related accuracies for each parameter of the radiometric models are described. To verify the accuracy of calibration parameters, a series of polarization detection accuracy verification experiments based on a non-polarized radiation source, a polarizing system, and a natural scene were carried out. The experimental results show that the maximum deviation of degree of polarization between the set values of the polarizing system and measured values of the DPC at the corresponding positions of four field of view angles of 0, 15, 30, and 45 degrees of each polarized spectral band is 0.009, 0.004, and 0.003, respectively. The average error in measuring the degree of polarization of a non-polarized light source by all pixels in the three polarized bands is 0.0043, 0.0046, and 0.0037, respectively. And the relative deviations of each field of view are within 0.020 when the DPC and CE318N simultaneously measure the DoLP of sky. All of these prove the effectiveness of the pre-flight calibration. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
WOS关键词RADIOMETRIC CALIBRATION ; GEOMETRIC CALIBRATION ; SELF-CALIBRATION ; LAND SURFACES ; DIGITAL CAMERAS ; IMAGING-SYSTEM ; AEROSOL ; POLDER ; ALGORITHM ; IMAGER
资助项目State Key Laboratory of Remote Sensing Science[GJTD-2018-15]
WOS研究方向Optics
语种英语
WOS记录号WOS:000530854700053
出版者OPTICAL SOC AMER
资助机构State Key Laboratory of Remote Sensing Science
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/103275]  
专题中国科学院合肥物质科学研究院
通讯作者Meng, Binghuan
作者单位1.Shanghai Inst Satellite Engn, Shanghai 200240, Peoples R China
2.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China
3.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
4.Chinese Acad Sci, Key Lab Opt Calibrat & Characterizat, Hefei 230031, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Huang, Chan,Xiang, Guangfeng,Chang, Yuyang,et al. Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera[J]. OPTICS EXPRESS,2020,28.
APA Huang, Chan.,Xiang, Guangfeng.,Chang, Yuyang.,Han, Lin.,Zhang, Miaomiao.,...&Hong, Jin.(2020).Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera.OPTICS EXPRESS,28.
MLA Huang, Chan,et al."Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera".OPTICS EXPRESS 28(2020).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。