中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Thermal analysis of beamline heat load components due to increased power delivery from EAST neutral beam injector

文献类型:期刊论文

作者Xu, Yongjian; Yu, Ling; Liang, Lizhen; Hu, Chundong; Xie, Yahong; Xie, Yuanlai; Jiang, Caichao; Liu, Sheng; Wei, Jianglong; Liu, Zhimin
刊名JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY
出版日期2020
卷号139
关键词Neutral beam Ion source Beam perveance Power delivery Beam divergence
ISSN号1388-6150
DOI10.1007/s10973-019-08292-8
通讯作者Yu, Ling(yuling@ipp.ac.cn)
英文摘要According to EAST's experimental plan, the long-pulse and high-power operation of neutral beam injector is the requirement for EAST. In this paper, the operation range of beam perveance is adjusted from 1.9-2.5 mu P to 2.5-3.3 mu P through changing the voltage ratio of gradient grid/plasma grid from 0.84 to 0.78. The thermal analysis of beamline heat load components shows that with the decrease in the voltage ratio of gradient grid/plasma grid from 0.84 to 0.78, the maximum neutral beam power deposition on the calorimeter increases from 825 to 950 kW when accelerating voltage is 50 kV. The results show that the minimum beam divergence increases from 1.25 degrees to 1.32 degrees and the maximum temperature rise of bending magnet collimator increases from 10 to 27 degrees C. The results in this paper are helpful to find a balance between increase in power delivery capability and prolongation of beam extraction duration and lay a basis for achieving plasma heating according to the physical experimental requirement of EAST.
WOS研究方向Thermodynamics ; Chemistry
语种英语
WOS记录号WOS:000512280800047
出版者SPRINGER
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/103919]  
专题中国科学院合肥物质科学研究院
通讯作者Yu, Ling
作者单位Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
推荐引用方式
GB/T 7714
Xu, Yongjian,Yu, Ling,Liang, Lizhen,et al. Thermal analysis of beamline heat load components due to increased power delivery from EAST neutral beam injector[J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY,2020,139.
APA Xu, Yongjian.,Yu, Ling.,Liang, Lizhen.,Hu, Chundong.,Xie, Yahong.,...&Tao, Ling.(2020).Thermal analysis of beamline heat load components due to increased power delivery from EAST neutral beam injector.JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY,139.
MLA Xu, Yongjian,et al."Thermal analysis of beamline heat load components due to increased power delivery from EAST neutral beam injector".JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY 139(2020).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。