英文摘要 | Residues in animal food and drinking water caused by the abuse of antibiotics lead to cell resistance and many chronic diseases in the human body. Therefore, it has become an inevitable trend to develop a fast, easy-to-use, on-site/real-time visualization method for the detection of antibiotics. Herein, we report a dual-response ra-tiometric fluorescence sensor which is fabricated by chelating europium ions (Eu3+) onto cadmium telluride quantum dots (CdTe QDs) for real-time and visible detection of tetracycline (TC). With the TC addition, the fluorescence of probe can be seen by the naked eye, from green to yellow and finally to red, exhibiting a dosage -sensitive and broad-chromatic detection strategy for TC. The fluorescence intensity ratio of I-616/I-512 of Eu/CdTe QDs sensor displays a good linear relation to TC concentrations in the range of 0-80 mu M with a limit of detection (LOD) of 2.2 nM. In addition, the sensor can visually detect 200 nM TC in actual samples, which is lower than the maximum residue limit (MRL) of the safety standard. The methodology reported here opens a window toward the real applications of fluorescent and shows the wide applicability in pursuing the concepts simple, rapid, visual, and real-time for food safety and environmental protection. |
WOS关键词 | TRACE LEVELS ; EMISSION ; RESIDUES ; SURFACES ; PLATFORM ; PROBE ; DNA |
资助项目 | National Natural Science Foundation of China[21876175] ; National Natural Science Foundation of China[21605144] ; National Natural Science Foundation of China[21806168] ; National Basic Research Program of China[2015CB932002] ; Key Research and Development Program of Anhui Province[1804a07020103] |
WOS研究方向 | Engineering ; Environmental Sciences & Ecology |
语种 | 英语 |
出版者 | ELSEVIER |
WOS记录号 | WOS:000568847200003 |
资助机构 | National Natural Science Foundation of China ; National Basic Research Program of China ; Key Research and Development Program of Anhui Province |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/104106] |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Yang, Liang; Wang, Zhenyang; Jiang, Changlong |
作者单位 | 1.Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China 2.State Ctr Qual Supervis & Inspect Camellia Prod, Ganzhou 341000, Jiangxi, Peoples R China 3.Chinese Acad Sci, State Key Lab Transducer Technol, Hefei 230031, Anhui, Peoples R China 4.Chinese Acad Sci, Inst Solid State Phys, Hefei Inst Phys Sci, Hefei 230031, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Han, Shuai,Yang, Liang,Wen, Zhigang,et al. A dual-response ratiometric fluorescent sensor by europium-doped CdTe quantum dots for visual and colorimetric detection of tetracycline[J]. JOURNAL OF HAZARDOUS MATERIALS,2020,398. |
APA | Han, Shuai.,Yang, Liang.,Wen, Zhigang.,Chu, Suyun.,Wang, Mei.,...&Jiang, Changlong.(2020).A dual-response ratiometric fluorescent sensor by europium-doped CdTe quantum dots for visual and colorimetric detection of tetracycline.JOURNAL OF HAZARDOUS MATERIALS,398. |
MLA | Han, Shuai,et al."A dual-response ratiometric fluorescent sensor by europium-doped CdTe quantum dots for visual and colorimetric detection of tetracycline".JOURNAL OF HAZARDOUS MATERIALS 398(2020). |
入库方式: OAI收割
来源:合肥物质科学研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。