中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Application of White Noise Perturbation in Wavelength Modulated Off-Axis Integrated Cavity Spectroscopy

文献类型:期刊论文

作者Wang Jing-jing1,2; Dong Yang2; Tian Xing2; Chen Jia-jin2; Tan Tu2; Zhu Gong-dong2; Mei Jiao-xu2; Gao Xiao-ming1,2
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
出版日期2020-09-01
卷号40
关键词Off-axis integrated cavity output spectroscopy Wavelength modulation RF white noise Cavity mode noise Detection limit
ISSN号1000-0593
DOI10.3964/j.issn.1000-0593(2020)09-2657-07
通讯作者Gao Xiao-ming(xmgao@aiofm.ac.cn)
英文摘要Off-axis integrated cavity output spectroscopy is an important method for trace gas detection, and its measurement limit is affected by residual cavity mode noise and background noise. In this paper, the residual mode noise in the output spectrum of OA-ICOS is reduced by injecting radio frequency (RF) white noise into the modulation current of the laser. Meanwhile, the influence of background signal is suppressed by wavelength modulation technology, and the signal-to-noise ratio of the OA-ICOS based methane sensor is further improved. Firstly, the influence of RF white noise with different power on the absorption spectra of methane in air is studied in detail, and the corresponding optimal modulation amplitude is calculated thought analyzing the linewidth of the absorption spectra. Subsequently, the influence of RF white noise with different power on 2f signal is studied. The results show that the baseline noise and 2f signal amplitude decrease simultaneously with the increase of RF noise power. By analyzing the signal-to-noise ratio of several sets of 2f signals, it is determined that the best power of RF white noise to improve the signal-to-noise ratio of the system is -25 dBm. Then, the relationship between methane concentration and the 2f signal in different concentration ranges was studied. The results show that the methane concentration is linear with 2f amplitude in the concentration range of less than 1.0 x 10(-6), and the methane concentration is in a curve relationship with the 2f signal in the concentration range of 0.1 similar to 2.2 x 10(-6). Subsequently, the stability of the system was investigated by measuring 2 2 x 10(-6) methane for a long time and Allan analysis of variance. The system has good stability, the optimal integration time is up to 1 250 s, and the corresponding minimum detectable limit is 1.2x10(-9). Finally, the methane concentration in the air out our laboratory was measured by using the built methane gas sensor for two days and nights. The results show that the diurnal variation of methane concentration is falling during the day and rising at night. The fluctuation range of methane concentration is 2.02x10(-6) similar to 2.3x10(-6), and the average concentration is 2.14 x 10(-6). This study provides a certain reference value for the application of off-axis integral cavity output spectroscopy in the measurement of the trace gas. It is of great significance for the development of high-precision in-situ trace gas measuring instruments.
WOS关键词OUTPUT SPECTROSCOPY ; LASER ; SENSITIVITY
WOS研究方向Spectroscopy
语种英语
WOS记录号WOS:000576358300001
出版者OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/104452]  
专题中国科学院合肥物质科学研究院
通讯作者Gao Xiao-ming
作者单位1.Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Hefei 230031, Peoples R China
2.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
推荐引用方式
GB/T 7714
Wang Jing-jing,Dong Yang,Tian Xing,et al. Application of White Noise Perturbation in Wavelength Modulated Off-Axis Integrated Cavity Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2020,40.
APA Wang Jing-jing.,Dong Yang.,Tian Xing.,Chen Jia-jin.,Tan Tu.,...&Gao Xiao-ming.(2020).Application of White Noise Perturbation in Wavelength Modulated Off-Axis Integrated Cavity Spectroscopy.SPECTROSCOPY AND SPECTRAL ANALYSIS,40.
MLA Wang Jing-jing,et al."Application of White Noise Perturbation in Wavelength Modulated Off-Axis Integrated Cavity Spectroscopy".SPECTROSCOPY AND SPECTRAL ANALYSIS 40(2020).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。