Methods and Error Analysis of Helium Pipe Temperature measurement in the EAST Superconducting Magnet System
文献类型:期刊论文
作者 | Qian J(钱静)1![]() ![]() |
刊名 | 低温物理学报
![]() |
出版日期 | 2014-02 |
关键词 | EAST SC magnet system He pipe temperature measurement error sources |
DOI | 10.13380/j.cnki.chin.j.lowtemp.phys.2014.01.006 |
英文摘要 | IntheEAST (abbr.ExperimentalAdvancedSuperconductingTokamak)device,operationaltempera- tureoftheSC(abbr.superconducting)magnetsystemiscloselyrelatedtothoseissueslikethermalloadcalculation andSCperformanceandoperationalstability.TemperatureonHe(abbr.Helium)coolingpipeisrequiredtoachieve accuratemeasurementsintheSCmagnetsystem.Thepaperfocusesonmethodsanderrorsourcesandtheirinflu- enceonHepipetemperaturemeasurement.Italsoputsforwardsomemethodstoreduceerrorsandthegoodexperi- mentalresultswhichhelpsatisfyengineeringrequirements.Themethodsdiscussedinthepapercanbeappliedtoall thecryogenicweaksignalmeasurements. |