Accuracy improvement of calibration-free laser-induced breakdown spectroscopy
文献类型:期刊论文
作者 | Fu, Hongbo1,3![]() |
刊名 | PLASMA SCIENCE & TECHNOLOGY
![]() |
出版日期 | 2019-03-01 |
期号 | 3页码:10 |
关键词 | CF-LIBS quantitative analysis accuracy self-absorption local thermodynamic equilibrium |
ISSN号 | 1009-0630 |
DOI | 10.1088/2058-6272/aaead6 |
英文摘要 | Calibration-free laser-induced breakdown spectroscopy can overcome the matrix effect and the huge application prospects of in situ and on-line measurement, so it has been studied and applied to many analytical samples by numerous researchers since it was first proposed in 1999. However, its accuracy is always lower than other analytical techniques and traditional quantitative analysis methods of laser-induced breakdown spectroscopy. The goal of this paper is to review the improvement of accuracy in the experimental setup and spectral analysis, especially after 2010, but not limited to it. The main contents include the accurate measurement of spectral intensity, the spatial and temporal window of local thermodynamic equilibrium and the accurate calculation of temperature and electron density. Due to the requirement of one or more standard samples, the combination of standard samples and CF-LIBS is discussed as a separate section. Finally, a simple conclusion is offered to relevant researchers who want to use CF-LIBS for quantitative analysis. |
WOS关键词 | LOCAL THERMODYNAMIC-EQUILIBRIUM ; EXPERIMENTAL STARK WIDTHS ; QUANTITATIVE ELEMENTAL ANALYSIS ; ARGON BRANCHING RATIOS ; SELF-ABSORPTION COEFFICIENTS ; ALUMINUM EMISSION-LINES ; INDUCED PLASMA ANALYSIS ; FREE INVERSE METHOD ; SPECTRAL-LINES ; SPATIAL CHARACTERIZATION |
资助项目 | National Natural Science Foundation of China[61505223] ; China State Key Lab. of Power System[SKLD18KM11] |
WOS研究方向 | Physics |
语种 | 英语 |
WOS记录号 | WOS:000451072800001 |
出版者 | IOP PUBLISHING LTD |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/40149] ![]() |
专题 | 合肥物质科学研究院_中科院安徽光学精密机械研究所 |
通讯作者 | Dong, Fengzhong |
作者单位 | 1.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Anhui, Peoples R China 2.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China 3.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Anhui Prov Key Lab Photon Devices & Mat, Hefei 230031, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Fu, Hongbo,Ni, Zhibo,Wang, Huadong,et al. Accuracy improvement of calibration-free laser-induced breakdown spectroscopy[J]. PLASMA SCIENCE & TECHNOLOGY,2019(3):10. |
APA | Fu, Hongbo,Ni, Zhibo,Wang, Huadong,Jia, Junwei,&Dong, Fengzhong.(2019).Accuracy improvement of calibration-free laser-induced breakdown spectroscopy.PLASMA SCIENCE & TECHNOLOGY(3),10. |
MLA | Fu, Hongbo,et al."Accuracy improvement of calibration-free laser-induced breakdown spectroscopy".PLASMA SCIENCE & TECHNOLOGY .3(2019):10. |
入库方式: OAI收割
来源:合肥物质科学研究院
其他版本