Preliminary result of cavity ring-down spectroscopy system for radio frequency negative ion source test facility
文献类型:期刊论文
作者 | Liang, Lizhen![]() ![]() ![]() ![]() |
刊名 | REVIEW OF SCIENTIFIC INSTRUMENTS
![]() |
出版日期 | 2019-12-01 |
卷号 | 90 |
ISSN号 | 0034-6748 |
DOI | 10.1063/1.5128096 |
通讯作者 | Liang, Lizhen(lzliang@ipp.ac.cn) |
英文摘要 | Negative ion source is a core part of the neutral beam injection system for magnetic confinement fusion devices. The density of produced hydrogen negative ions is a critical parameter of the negative ion source. Cavity ring-down spectroscopy (CRDS) is an ultrasensitive absorption diagnostic technique for density measurement. Based on the photodetachment process, CRDS can measure the integrated line-of-sight hydrogen negative ion density in a high power ion source. The CRDS diagnostic system has been applied to Hefei utility negative ion test equipment with the radio frequency (RF) source, which is now one of the references for the China Fusion Engineering Test Reactor neutral beam injection system. Typical ring-down signals are obtained to calculate the density of hydrogen negative ions. The time evolution of hydrogen negative ion density is successfully measured. Preliminary experiments show the accurate relationship between RF power and measured hydrogen negative ion density. |
WOS关键词 | DESIGN |
资助项目 | National Natural Science Foundation of China[11675216] ; National Natural Science Foundation of China[11575240] ; National Key R&D Program of China[2017YFE300103] ; National Key R&D Program of China[2017YFE300503] |
WOS研究方向 | Instruments & Instrumentation ; Physics |
语种 | 英语 |
WOS记录号 | WOS:000505597900002 |
出版者 | AMER INST PHYSICS |
资助机构 | National Natural Science Foundation of China ; National Key R&D Program of China |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/42909] ![]() |
专题 | 合肥物质科学研究院_中科院固体物理研究所 |
通讯作者 | Liang, Lizhen |
作者单位 | Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China |
推荐引用方式 GB/T 7714 | Liang, Lizhen,Hu, Chundong,Yan, Jingyang,et al. Preliminary result of cavity ring-down spectroscopy system for radio frequency negative ion source test facility[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2019,90. |
APA | Liang, Lizhen,Hu, Chundong,Yan, Jingyang,Zhao, Yuanzhe,&Xie, Yahong.(2019).Preliminary result of cavity ring-down spectroscopy system for radio frequency negative ion source test facility.REVIEW OF SCIENTIFIC INSTRUMENTS,90. |