中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor

文献类型:期刊论文

作者Luo Wei1,3; Sun Feng-long1,3; Liu Jia-rui2; Hou Jun-wu1,3; Wang Ben-gan1,3; Huang Xiao-ping1,3
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
出版日期2018-06-01
卷号38期号:6页码:1982-1986
关键词Temperature RI Matrix measurement Parallel light path Surface Plasmon Resonance
ISSN号1000-0593
DOI10.3964/j.issn.1000-0593(2018)06-1982-05
英文摘要

An angle scanning prism-based SPR sensor system is proposed in this paper. With the structure of reflex parallel light path, the system has been simplified, which mainly consists of light source, CCD sensor, parallel light path structure, rotation and temperature control module. With the motor scanning incidence angle and temperature control, an effective measurement of glucose refractive index (RI) mass concentration property can be achieved. Moreover, a theoretical model has been established to explain the existence of a sensitivity matrix, which enables both the RI and temperature to be measured and obtained from proof-of-concept experiment. This approach paves a way for conventional SPR-based sensors to discriminate between RI-induced and temperature-induced SPR changes and provides a reference for the correction of temperature interference.

WOS关键词DNA
资助项目Natural Science Key Foundation, Department of Education, Anhui Province[KJ2016A305] ; National Science and Technology Support Program[2014BAD08B11]
WOS研究方向Spectroscopy
语种英语
WOS记录号WOS:000435531000057
出版者OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/38359]  
专题合肥物质科学研究院_中科院合肥智能机械研究所
通讯作者Luo Wei
作者单位1.Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Inst Intelligent Machines, Hefei 230031, Anhui, Peoples R China
推荐引用方式
GB/T 7714
Luo Wei,Sun Feng-long,Liu Jia-rui,et al. Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2018,38(6):1982-1986.
APA Luo Wei,Sun Feng-long,Liu Jia-rui,Hou Jun-wu,Wang Ben-gan,&Huang Xiao-ping.(2018).Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor.SPECTROSCOPY AND SPECTRAL ANALYSIS,38(6),1982-1986.
MLA Luo Wei,et al."Matrix Measurement of Glucose Concentration Based on Surface Plasmon Resonance Sensor".SPECTROSCOPY AND SPECTRAL ANALYSIS 38.6(2018):1982-1986.

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。