Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer
文献类型:期刊论文
作者 | Yu Jia-Jun3; Liu Ping4; Zeng Zhen3; Chen Ying3; Gao Wei1,3; Li Mei1,3; Wang Chen-Guang2; Huang Zheng-Xu1,3; Zhou Zhen1,3; Li Lei1,3 |
刊名 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
![]() |
出版日期 | 2018-04-01 |
卷号 | 46期号:4页码:463-470 |
关键词 | Matrix-assisted laser desorption ionization Linear time-of-flight mass spectrometer Development Performance characterization |
ISSN号 | 0253-3820 |
DOI | 10.1016/S1872-2040(17)61077-6 |
通讯作者 | Li Lei(lileishdx@163.com) |
英文摘要 | Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an important analytical technique for biological macromolecules, such as proteins, peptides and nucleic acid, especially in the field of microbial identification. On the basis of previous study, a linear MALDI-TOF MS was been designed and assembled for biological applications. The instrument comprised a vacuum system, a vacuum fast sample introduction system, an optical system, a time-of-flight mass analyzer, an ion source, a data acquisition system and an electronic control system. The ion source adopted two-stage source acceleration, delayed extraction and dynamic pulse focusing technique. The time-of-flight distance of field-free drift region was about 1 m. The optical system adopted a solid-state laser with adjustable frequency of 1-2000 Hz and spots of 20-100 mu m. The angle of incidence laser was controlled at 5 degrees. A series of experiments were carried out to further evaluate the instrument performances. It could not only analyze the samples more than 199 kDa, but also achieve isotope resolution at 1000-3000 Da and up to 900 (FWHM) at 5000-17000 Da. The minimum detectable concentration of gramicidin was 10 amol mu L-1, absolute sensitivity reached up to 2.56 amol. Independent detection of saliva samples from different targets showed that the instrument had higher producibility. We identified Escherichia coli and Shigella spp., which are two common bacteria but difficult to be differentiated by mass spectrometry, showing its potential identification for clinical microorganism. In summary, this instrument can play a role on clinical examination in the near future. |
WOS关键词 | MALDI-TOF MS ; ESCHERICHIA-COLI ; ION FORMATION ; VITEK MS ; TIME ; IDENTIFICATION ; DESORPTION/IONIZATION ; BIOTYPER ; EXTRACTION ; RESOLUTION |
资助项目 | Guangdong Applied Science and Technology Research and Development, China[2015B020236003] ; Fundamental Research Funds for the Central Universities of China[21616341] |
WOS研究方向 | Chemistry |
语种 | 英语 |
WOS记录号 | WOS:000434467300002 |
出版者 | ELSEVIER SCIENCE INC |
资助机构 | Guangdong Applied Science and Technology Research and Development, China ; Fundamental Research Funds for the Central Universities of China |
源URL | [http://ir.giec.ac.cn/handle/344007/23417] ![]() |
专题 | 中国科学院广州能源研究所 |
通讯作者 | Li Lei |
作者单位 | 1.Guangdong Prov Engn Res Ctr On Line Source Apport, Guangzhou 510632, Guangdong, Peoples R China 2.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China 3.Jinan Univ, Inst Mass Spectrometer & Atmospher Environm, Guangzhou 510632, Guangdong, Peoples R China 4.Guangzhou HeXin Instrument Co LTD, Guangzhou 510530, Guangdong, Peoples R China |
推荐引用方式 GB/T 7714 | Yu Jia-Jun,Liu Ping,Zeng Zhen,et al. Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2018,46(4):463-470. |
APA | Yu Jia-Jun.,Liu Ping.,Zeng Zhen.,Chen Ying.,Gao Wei.,...&Li Lei.(2018).Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,46(4),463-470. |
MLA | Yu Jia-Jun,et al."Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 46.4(2018):463-470. |
入库方式: OAI收割
来源:广州能源研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。