中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Thermal Environment Analysis and Improvement on Isolated Cold Aisle Data Centers

文献类型:期刊论文

作者Su, Lin2,3,4; Huang, Zhilin1,2,3,4; Dong, Kaijun2,3,4
刊名JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS
出版日期2020-08-01
卷号12期号:4页码:9
关键词data center thermal environment numerical simulation isolated cold aisle airflow distribution energy efficiency heat transfer enhancement thermal systems
ISSN号1948-5085
DOI10.1115/1.4045746
通讯作者Dong, Kaijun(sulin@ms.giec.ac.cn)
英文摘要Isolated cold aisle airflow distribution is a transitional form from non-isolated airflow distribution to closed cold aisle airflow distribution. With the increase of the power of racks, cooling failure may happen in the layout of the isolated cold aisle. This paper presents the study on cooling performance of the racks which are improved through bottom ventilating reform and adjustment. Inlet/outlet air temperature and mass flow rate of the racks are investigated in detail under conditions of various bottom ventilated areas and various porosities of the raised floor. The characteristics of airflow distribution are contrastively analyzed through calculating indexes of the thermal environment of data centers. Results show that adequate ventilation through the bottom of the racks is good for improvement of the state of airflow distribution. There is an optimization range (0.1-0.3 m and 0.05-0.15 m, respectively) of the ventilated area at the bottom of the racks. And high porosity (above 50%) of the ventilated area can reduce the inlet and outlet temperatures of the racks and the racks in different positions have a better temperature uniformity. In conclusion, bottom ventilation of racks is a feasible plan to improve airflow distribution, and schemes of ventilated area and porosity of corresponding raised floor should be designed respectively under consideration of the layout of racks and AC.
WOS关键词AIR-DISTRIBUTION SYSTEMS ; FLOW ; PERFORMANCE ; MANAGEMENTS
资助项目Science and Technology Planning Project of Guangzhou, China[201902010031] ; International Cooperation Project of Guangzhou Development District[2018GH05]
WOS研究方向Thermodynamics ; Engineering
语种英语
WOS记录号WOS:000549858300027
出版者ASME
资助机构Science and Technology Planning Project of Guangzhou, China ; International Cooperation Project of Guangzhou Development District
源URL[http://ir.giec.ac.cn/handle/344007/27496]  
专题中国科学院广州能源研究所
通讯作者Dong, Kaijun
作者单位1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
2.Guangdong Prov Key Lab New & Renewable Energy Res, Guangzhou 510640, Peoples R China
3.CAS Key Lab Renewable Energy, Guangzhou 510640, Peoples R China
4.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China
推荐引用方式
GB/T 7714
Su, Lin,Huang, Zhilin,Dong, Kaijun. Thermal Environment Analysis and Improvement on Isolated Cold Aisle Data Centers[J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS,2020,12(4):9.
APA Su, Lin,Huang, Zhilin,&Dong, Kaijun.(2020).Thermal Environment Analysis and Improvement on Isolated Cold Aisle Data Centers.JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS,12(4),9.
MLA Su, Lin,et al."Thermal Environment Analysis and Improvement on Isolated Cold Aisle Data Centers".JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS 12.4(2020):9.

入库方式: OAI收割

来源:广州能源研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。