英文摘要

Cerenkov emission during electron radiotherapy had been emerging as a new dose assessment approach for clinical radiotherapy and could be imaged through a standard commercial camera. The purpose of this work aimed to study the accuracy of corrected Cerenkov emission method during electron radiotherapy by Monte Carlo (MC) method. GAMOS MC software was used to model the physics of electron therapy and calculated dose and Cerenkov photon distribution in water phantom. Compared to ionization chamber and diode measurement, MC simulated dose discrepancy was less than 1% in percentage depth dose (PDD) curves and less than. 2% in crossline profile curves, which was acceptable for clinical criterion. Compared to ionization chamber dose measurement, MC simulated Cerenkov discrepancy was less than 2% in crossline profile distribution, which was acceptable for clinical criterion. However, the Cerenkov PDD curves tended to overestimate the dose at the build-up region and underestimate the dose at the remaining attenuation region. After increasing the Cerenkov distribution depth to 2–3 mm, the discrepancy became well within 1% at the remaining attenuation region, which was acceptable for clinical criterion. Therefore, corrected Cerenkov emission could be used to assess PDD accuracy and crossline profile accuracy during electron radiotherapy. © 2020 Elsevier Ltd

语种英语
出版者Elsevier Ltd
源URL[http://ir.opt.ac.cn/handle/181661/93771]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
通讯作者Liu, Hongjun; Zhang, Chunmin
作者单位1.University of Chinese Academy of Science, Beijing; 100084, China
2.Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan; 030006, China;
3.School of Physics, Xi'an Jiaotong University, Xi'an; 710049, China;
4.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China;
推荐引用方式
GB/T 7714
Li, Yi,Liu, Hongjun,Huang, Nan,et al. Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method[J]. Applied Radiation and Isotopes,2020.
APA Li, Yi,Liu, Hongjun,Huang, Nan,Wang, Zhaolu,&Zhang, Chunmin.(2020).Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method.Applied Radiation and Isotopes.
MLA Li, Yi,et al."Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method".Applied Radiation and Isotopes (2020).

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。