Ultra-sensitive determination of antimony valence by solution cathode glow discharge optical emission spectrometry coupled with hydride generation
文献类型:期刊论文
作者 | Zhao, MY; Peng, XX; Yang, BC; Wang, Z |
刊名 | JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
![]() |
出版日期 | 2020-06-01 |
期号 | 6页码:1148 |
ISSN号 | 0267-9477 |
DOI | 10.1039/d0ja00009d |
文献子类 | Article |
英文摘要 | An ultra-sensitive solution cathode glow discharge-optical emission spectrometry (SCGD-OES) method coupled with hydride generation (HG) for the determination of antimony valence is described. Through masking Sb(v) with citric acid in HCl medium, stibine from Sb(iii) was selectively generated in a hydride generation system. Total antimony was determined after reducing Sb(v) to Sb(iii) with 0.3%l-cysteine in 0.01 mol L-1HCl. The Sb(v) concentration was calculated from the difference between total antimony and Sb(iii). The main operational parameters and sources of potential interference that affect the determination were optimized with Sb(iii) standard solution. The limits of detection (LODs) were 0.39 and 0.36 ng mL(-1)for Sb(iii) and total antimony, respectively, and the RSDs were 2.1 and 1.7% at the 10 ng mL(-1)level, respectively. This method was applied for determining the valence of antimony in real water samples, and recovery experiments for different amounts of analytes were carried out. The recoveries were all in the range of 96.2-103.2% and were in good agreement with the corresponding ICP-MS values. |
WOS关键词 | ATOMIC FLUORESCENCE SPECTROMETRY ; TRACE DETERMINATION ; ELEMENTAL ANALYSIS ; ONLINE SEPARATION ; HUNAN PROVINCE ; WATER SAMPLES ; PLASMA ; SPECIATION ; SB ; ABSORPTION |
WOS研究方向 | Chemistry ; Spectroscopy |
语种 | 英语 |
出版者 | ROYAL SOC CHEMISTRY |
源URL | [http://ir.sic.ac.cn/handle/331005/28007] ![]() |
专题 | 中国科学院上海硅酸盐研究所 |
推荐引用方式 GB/T 7714 | Zhao, MY,Peng, XX,Yang, BC,et al. Ultra-sensitive determination of antimony valence by solution cathode glow discharge optical emission spectrometry coupled with hydride generation[J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY,2020(6):1148. |
APA | Zhao, MY,Peng, XX,Yang, BC,&Wang, Z.(2020).Ultra-sensitive determination of antimony valence by solution cathode glow discharge optical emission spectrometry coupled with hydride generation.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY(6),1148. |
MLA | Zhao, MY,et al."Ultra-sensitive determination of antimony valence by solution cathode glow discharge optical emission spectrometry coupled with hydride generation".JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY .6(2020):1148. |
入库方式: OAI收割
来源:上海硅酸盐研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。