Liquid chromatography-tandem mass spectrometric assay for TPN171 in human plasma
文献类型:期刊论文
作者 | Zhang, Mengqi1,2; Liu, Haiming1,2; He, Jiajin1,2; Gui, Yuzhou1,2; Qian, Hongjie1,2; Jia, Jingying1,2; Yu, Chen1,2; Wang, Zhen3![]() |
刊名 | JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
![]() |
出版日期 | 2020-11-30 |
卷号 | 191页码:8 |
关键词 | TPN171 LC-MS/MS Human plasma Protein precipitation |
ISSN号 | 0731-7085 |
DOI | 10.1016/j.jpba.2020.113634 |
通讯作者 | Liu, Gangyi(gyliu@shxh-centerlab.com) |
英文摘要 | A simple, rapid and accurate method for quantitative analysis of a highly selective phosphodiesterase-5 inhibitor (PDE5), TPN171 by high performance liquid chromatography and tandem mass spectrometry in human plasma was proposed and validated successfully using D-3-TPN171 as internal standards (ISTD). An aliquot of 100 mu L of plasma was mixed with internal standard and was precipitated with acetonitrile. Gradient elution was performed on a ACQUITY HSS T3 column (50 x 2.1 mm, 1.8 pin) coupled with a ACQUITY column in-line filter at 40 degrees C, by 5 mM ammonium acetate in water containing 0.1 % formic acid and 0.1 % formic acid in acetonitrile as the mobile phase. The total analytical run time was 3.5 min. The analyte was monitored using multiple reaction monitoring (MRM) scan in positive polarity mode. The ion transition was m/z 442.2 -> 113.2 and 445.2 -> 116.2 for TPN171 and D-3-TPN171 respectively. The method was validated for specificity, sensitivity, precision, accuracy, and other analytical parameters. The results found were satisfactory over the linear calibration range of 1-500 ng/mL. Within-day precisions ranged from 1.8 to 7.3 %, and between-day precisions from 2.3 to 4.9 %, accuracies were 95.5-99.8 %.The validated method was successfully applied to determine the plasma concentration after oral administration of 10 mg TPN171 in six healthy volunteers. (C) 2020 Elsevier B.V. All rights reserved. |
WOS关键词 | SELECTIVE PDE5 INHIBITOR ; TADALAFIL ; HYPERTENSION ; SILDENAFIL ; DISCOVERY |
WOS研究方向 | Chemistry ; Pharmacology & Pharmacy |
语种 | 英语 |
WOS记录号 | WOS:000579528000060 |
出版者 | ELSEVIER |
源URL | [http://119.78.100.183/handle/2S10ELR8/292608] ![]() |
专题 | 中国科学院上海药物研究所 |
通讯作者 | Liu, Gangyi |
作者单位 | 1.Fudan Univ, Zhongshan Xuhui Hosp, Shanghai Xuhui Cent Hosp, Shanghai 200031, Peoples R China 2.Shanghai Engn Res Ctr Phase I Clin Res & Qual Con, Shanghai 200031, Peoples R China 3.Chinese Acad Sci, Shanghai Inst Mat Med, CAS Key Lab Receptor Res, 555 Zuchongzhi Rd, Shanghai 201203, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Mengqi,Liu, Haiming,He, Jiajin,et al. Liquid chromatography-tandem mass spectrometric assay for TPN171 in human plasma[J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,2020,191:8. |
APA | Zhang, Mengqi.,Liu, Haiming.,He, Jiajin.,Gui, Yuzhou.,Qian, Hongjie.,...&Liu, Gangyi.(2020).Liquid chromatography-tandem mass spectrometric assay for TPN171 in human plasma.JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,191,8. |
MLA | Zhang, Mengqi,et al."Liquid chromatography-tandem mass spectrometric assay for TPN171 in human plasma".JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS 191(2020):8. |
入库方式: OAI收割
来源:上海药物研究所
浏览0