Study on Spectral Interference in the Determination of Vanadium by ICP-OES

文献类型:期刊论文

作者Wang Shao-na5; Jin Xing4; Liu Biao5; Zhao Bei-bei3; Li Lan-jie3; Li Ming2; Du Hao1,5; Zhang Yi5
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
出版日期2020-07-01
卷号40期号:7页码:2283-2288
关键词ICP-OES Vanadium Vanadium titanomagnetite Stone coal
ISSN号1000-0593
DOI10.3964/j.issn.1000-0593(2020)07-2283-06
英文摘要Vanadium is an important scarce resource and strategic metal, and often coexists with a variety of complex metals in the form of secondary mineral phases in nature. The effect of co-exist elements on the selection of spectral lines in the determination of vanadium with Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-OES) was studied in this article. The selected PE Optima 7300V instrument was operated under the conditions of incident power 1 300 W, observation height 15 mm and atomization gas flow rate 0.65 L . min(-1). The results show that Al, Mo, Ti, Cr and Ni have significant effects on the determination of vanadium under six recommended spectral lines, and the relationship between the relative error of measurement results and the mass ratio of the corresponding element to V waslinear. The presence of trace Al leads to drastic changes when V 309.31 nm spectral lines was adopted. The relative error of V 290.88 and V 292.402 nm spectral lines were increased to more than +/- 5% as the Mo/V mass ratio increased to 0.89 and 5.98, separately. The Mo measurement results were unstable when V 270.093 nm spectral lines was adopted, but nothing regular. The relative error of V 311.07, 290.88, 270.093 and 310.23 nm spectral lines were increased to more than +/- 5% as the Ti/V mass ratio increased to 5.98, Cr/V mass ratio increased to 10. 33, 13. 6, and Ni/V mass ratio increased to 13. 56, respectively. Considering the above effects and spectral stability, V 311.07 nm spectral lines can be adopted when there has no titanium in vanadium-containing raw materials, and V 310.23 nm can be used when there has titanium contained. Under the optimum analytical conditions of the spectrometer, the method was used for the determination of vanadium in typical vanadium-containing raw materials such as vanadium-titanium magnetite, stone coal and vanadium-containing catalysts with the detection limit of 0.054 mg . L-1 at 310.23 nm, 0.194 mg . L-1 at 311.07 nm, recoveries between 93.4% and 103.1% , and relative standard deviation of 0.59%. By comparing with the results of ammonium ferrous sulfate titration method, the results were basically consistent with the relative error of less than +/- 4.34%. In conclusion, the method was simple and efficient, with high precision and accuracy, which can be used for research and routine production of vanadium determination in raw materials containing vanadium.
WOS研究方向Spectroscopy
语种英语
WOS记录号WOS:000556010000049
出版者OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS
源URL[http://ir.ipe.ac.cn/handle/122111/41712]  
专题中国科学院过程工程研究所
通讯作者Du Hao
作者单位1.Univ Chinese Acad Sci, Int Coll, Beijing 100049, Peoples R China
2.Pangang Grp Res Inst Co Ltd, Panzhihua 617000, Peoples R China
3.HBIS Grp Co Ltd, Chengde V & Ti New Mat Co Ltd, Chengde 067102, Peoples R China
4.Kunming Univ Sci & Technol, Fac Met & Energy Engn, Kunming 650500, Yunnan, Peoples R China
5.Chinese Acad Sci, Inst Proc Engn, Key Lab Green Proc & Engn, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Wang Shao-na,Jin Xing,Liu Biao,et al. Study on Spectral Interference in the Determination of Vanadium by ICP-OES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2020,40(7):2283-2288.
APA Wang Shao-na.,Jin Xing.,Liu Biao.,Zhao Bei-bei.,Li Lan-jie.,...&Zhang Yi.(2020).Study on Spectral Interference in the Determination of Vanadium by ICP-OES.SPECTROSCOPY AND SPECTRAL ANALYSIS,40(7),2283-2288.
MLA Wang Shao-na,et al."Study on Spectral Interference in the Determination of Vanadium by ICP-OES".SPECTROSCOPY AND SPECTRAL ANALYSIS 40.7(2020):2283-2288.

入库方式: OAI收割

来源:过程工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。