Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel
文献类型:期刊论文
作者 | Peng, Di2; Liu, Xu2; Jiao, Lingrui2; Li, Ziyan2; Wen, Xin2; Yuan CK(苑朝凯)1![]() ![]() ![]() ![]() |
刊名 | ACTA MECHANICA SINICA
![]() |
出版日期 | 2021-01-25 |
页码 | 7 |
关键词 | Temperature-sensitive paint Time-resolved measurement Hypersonic flow Background radiation |
ISSN号 | 0567-7718 |
DOI | 10.1007/s10409-021-01050-w |
通讯作者 | Yuan, Chaokai(yuanck@imech.ac.cn) ; Liu, Yingzheng() |
英文摘要 | The strong background radiation in high enthalpy hypersonic shock tunnels has posed severe challenges for measurement using luminescent coatings. We proposed a solution for reducing background radiation from time-resolved temperature-sensitive paint (TSP) measurement in a hypersonic flow with Ma = 6.5 and T-0 = 3525 K. The TSP was applied on an inlet ramp model, and the images were taken by a high-speed camera at 2 kHz under a modulated excitation. The strong background radiation led to a low signal-to-noise ratio and significant errors for the first half of the 130-ms test duration. Accordingly, three noise reduction methods were developed and evaluated based on temporal reconstruction, spatial reconstruction and robust principal component analysis (RPCA), respectively. The RPCA method showed the best performance that successfully recovered high-quality TSP data for a majority of test duration (t >= 40 ms). |
分类号 | 二类 |
资助项目 | National Natural Science Foundation of China[11725209] ; National Natural Science Foundation of China[11872038] ; Gas Turbine Research Institute of Shanghai Jiao Tong University |
WOS研究方向 | Engineering ; Mechanics |
语种 | 英语 |
WOS记录号 | WOS:000611435000001 |
资助机构 | National Natural Science Foundation of China ; Gas Turbine Research Institute of Shanghai Jiao Tong University |
其他责任者 | Yuan, Chaokai ; Liu, Yingzheng |
源URL | [http://dspace.imech.ac.cn/handle/311007/86019] ![]() |
专题 | 力学研究所_高温气体动力学国家重点实验室 |
作者单位 | 1.Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China 2.Shanghai Jiao Tong Univ, Sch Mech Engn, Gas Turbine Res Inst, Shanghai 200240, Peoples R China; |
推荐引用方式 GB/T 7714 | Peng, Di,Liu, Xu,Jiao, Lingrui,et al. Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel[J]. ACTA MECHANICA SINICA,2021:7. |
APA | Peng, Di.,Liu, Xu.,Jiao, Lingrui.,Li, Ziyan.,Wen, Xin.,...&姜宗林.(2021).Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel.ACTA MECHANICA SINICA,7. |
MLA | Peng, Di,et al."Noise reduction for temperature-sensitive paint measurement contaminated by strong background radiation in a high enthalpy hypersonic tunnel".ACTA MECHANICA SINICA (2021):7. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。