Thermal conductivity of closed-cell aluminum alloy foam
文献类型:期刊论文
刊名 | ACTA METALLURGICA SINICA
![]() |
出版日期 | 2003 |
卷号 | 39 |
关键词 | METAL FOAMS DEFORMATION ABSORPTION closed-cell aluminum alloy foam porosity cell size thermal conductivity |
ISSN号 | 0412-1961 |
其他题名 | Thermal conductivity of closed-cell aluminum alloy foam |
英文摘要 | The thermal conductivity of aluminum alloy foam has been measured as a function of cell size and relative density. The results show that the thermal conductivity of foam rapidly decreases with the increase of porosity and is about 1/30-1/80 of the solid material. The cell size has a minor influence on the thermal conductivity of foam and appears to have a negligible effect. The dependence of the thermal conductivity of aluminum alloy foam on porosity can be described by the series-parallel and the parallel-series models. The experimental results show that the series-parallel model is more suitable. |
语种 | 英语 |
CSCD记录号 | CSCD:1267035 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/64797] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
推荐引用方式 GB/T 7714 | . Thermal conductivity of closed-cell aluminum alloy foam[J]. ACTA METALLURGICA SINICA,2003,39. |
APA | (2003).Thermal conductivity of closed-cell aluminum alloy foam.ACTA METALLURGICA SINICA,39. |
MLA | "Thermal conductivity of closed-cell aluminum alloy foam".ACTA METALLURGICA SINICA 39(2003). |