The electron temperature estimation using soft x-ray imaging in HT-7 tokamak

文献类型:期刊论文

刊名PLASMA SCIENCE & TECHNOLOGY
出版日期2006
卷号8
关键词TFTR different foils technique soft x-ray electron temperature tokamak plasma
ISSN号1009-0630
其他题名The Electron Temperature Estimation Using Soft X-Ray Imaging in HT-7 Tokamak
英文摘要In order to estimate the electron temperature soft x-ray imaging diagnostics using a double filter technique has been developed in the HT-7 tokamak. The chosen thicknesses of the Be foil are 12.5 mu m and 70 mu m, respectively. In this article both the main design of the diagnostic configuration and the method to estimate the electron temperature are presented. The results agree with those estimated from the soft x-ray pulse height analyzer (PHA). The main causes of systematic error have also been investigated.