The electron temperature estimation using soft x-ray imaging in HT-7 tokamak
文献类型:期刊论文
刊名 | PLASMA SCIENCE & TECHNOLOGY
![]() |
出版日期 | 2006 |
卷号 | 8 |
关键词 | TFTR different foils technique soft x-ray electron temperature tokamak plasma |
ISSN号 | 1009-0630 |
其他题名 | The Electron Temperature Estimation Using Soft X-Ray Imaging in HT-7 Tokamak |
英文摘要 | In order to estimate the electron temperature soft x-ray imaging diagnostics using a double filter technique has been developed in the HT-7 tokamak. The chosen thicknesses of the Be foil are 12.5 mu m and 70 mu m, respectively. In this article both the main design of the diagnostic configuration and the method to estimate the electron temperature are presented. The results agree with those estimated from the soft x-ray pulse height analyzer (PHA). The main causes of systematic error have also been investigated. |
语种 | 英语 |
CSCD记录号 | CSCD:2631539 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/57876] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
推荐引用方式 GB/T 7714 | . The electron temperature estimation using soft x-ray imaging in HT-7 tokamak[J]. PLASMA SCIENCE & TECHNOLOGY,2006,8. |
APA | (2006).The electron temperature estimation using soft x-ray imaging in HT-7 tokamak.PLASMA SCIENCE & TECHNOLOGY,8. |
MLA | "The electron temperature estimation using soft x-ray imaging in HT-7 tokamak".PLASMA SCIENCE & TECHNOLOGY 8(2006). |
入库方式: OAI收割