Electromagnetic Design and Mechanical Behavior Analysis of an 850 MHz All REBCO Nuclear Magnetic Resonance Magnet

文献类型:期刊论文

作者Li, Da1,3; Wang, Hongzhi1; Ren, Yong2; Wang, Dongquan2,3
刊名IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
出版日期2021-04-01
卷号31
ISSN号1051-8223
关键词Double-pancake (DP) magnetic field homogeneity mechanical behavior analysis nuclear magnetic resonance(NMR ) coil REBCO coil superconducting magnet
DOI10.1109/TASC.2021.3052825
通讯作者Wang, Hongzhi(wanghz@hfcas.ac.cn) ; Ren, Yong(renyong@mail.ustc.edu.cn)
英文摘要A 20 T/phi 32 mm all REBa2CL3O7-delta (REBCO, RE = rare earth) REBCO superconducting magnet for 850 MHz nuclear magnetic resonance spectroscopy is being designed. The high-temperature superconductors, REBCO-coated conductors with both high tensile stress and high critical current density under high magnetic field would allow superconducting magnets to be compact and lighter than their low-temperature superconductor counterparts. The 20-T REBCO superconducting magnet consists of a stack of 28 double-pancake coils with the so-called no-insulation methods. Considering the perpendicular magnetic field to the c-axis, five different width tapes, i.e., 4.1, 5.1, 6.1, 7.1, and 8.1 mm were placed on the midplane to both end positions in an axial direction. To improve the magnetic field homogeneity. the inside notch on the 4.1-mm tapes was adopted. The peak-to-peak magnetic field homogeneity over a 5-mm diameter spherical volume is better than 0.8 ppm. In this article, the design of the REBCO coils, electromagnetic field analysis, and stress analysis of the superconducting coils were presented.
资助项目National Natural Science Foundation of China[51406215]
WOS研究方向Engineering ; Physics
语种英语
出版者IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
WOS记录号WOS:000622097000002
资助机构National Natural Science Foundation of China
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/120352]  
专题中国科学院合肥物质科学研究院
通讯作者Wang, Hongzhi; Ren, Yong
作者单位1.Chinese Acad Sci, Caner Hosp, Inst Hlth & Med Technol, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
2.Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
3.Univ Sci & Technol China, Hefei 230026, Peoples R China
推荐引用方式
GB/T 7714
Li, Da,Wang, Hongzhi,Ren, Yong,et al. Electromagnetic Design and Mechanical Behavior Analysis of an 850 MHz All REBCO Nuclear Magnetic Resonance Magnet[J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY,2021,31.
APA Li, Da,Wang, Hongzhi,Ren, Yong,&Wang, Dongquan.(2021).Electromagnetic Design and Mechanical Behavior Analysis of an 850 MHz All REBCO Nuclear Magnetic Resonance Magnet.IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY,31.
MLA Li, Da,et al."Electromagnetic Design and Mechanical Behavior Analysis of an 850 MHz All REBCO Nuclear Magnetic Resonance Magnet".IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY 31(2021).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。