Progress on final design of ITER radial X-ray camera
文献类型:期刊论文
作者 | Chen, Kaiyun1![]() ![]() ![]() ![]() ![]() |
刊名 | FUSION ENGINEERING AND DESIGN
![]() |
出版日期 | 2021-04-01 |
卷号 | 165 |
关键词 | ITER Diagnostic Radial x-ray camera |
ISSN号 | 0920-3796 |
DOI | 10.1016/j.fusengdes.2021.112234 |
通讯作者 | Hu, Liqun(lqhu@ipp.ac.cn) ; Cao, Hongrui(caohr@ipp.ac.cn) |
英文摘要 | The design of ITER Radial X-ray Camera (RXC) is nearly finished. The design of internal camera was updated using gas detector modules and considering the mechanical, electrical and gas interfaces with Diagnostic Shielding Module (DSM). The design of camera structure was optimized for the purpose of easy maintenance, safety and simplification, including support flange, Be window flange, boron carbide shielding module, external camera chamber, back flange assembly, cooling and feedthrough. The design of camera electronics was also optimized. The pre-amplifiers and mid-amplifiers are more resistant to disturbances. The chassis facilitates the maintenance and provides efficient cooling to the components inside. |
WOS研究方向 | Nuclear Science & Technology |
语种 | 英语 |
WOS记录号 | WOS:000632658900005 |
出版者 | ELSEVIER SCIENCE SA |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/121343] ![]() |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Hu, Liqun; Cao, Hongrui |
作者单位 | 1.Chinese Acad Sci, Inst Plasma Phys, Hefei, Peoples R China 2.China Int Nucl Fus Energy Program Execut Ctr, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Kaiyun,Hu, Liqun,Yu, Hong,et al. Progress on final design of ITER radial X-ray camera[J]. FUSION ENGINEERING AND DESIGN,2021,165. |
APA | Chen, Kaiyun.,Hu, Liqun.,Yu, Hong.,Cao, Hongrui.,Li, Shi.,...&Fang, Tongzhen.(2021).Progress on final design of ITER radial X-ray camera.FUSION ENGINEERING AND DESIGN,165. |
MLA | Chen, Kaiyun,et al."Progress on final design of ITER radial X-ray camera".FUSION ENGINEERING AND DESIGN 165(2021). |