英文摘要AbstractSingle-mode magnetic resonance imaging (MRI) contrast agents (CAs) in clinical settings are easily disturbed by calcification, bleeding, and adipose signals, which result in inaccurate diagnoses. In this study, we developed a highly efficient T1–T2 dual-mode MRI CA using an ultra-small gadolinium oxide-decorated magnetic iron oxide nanocrystal (GMIO). The gadolinium element could effectively alter the magnetic properties of the GMIO from soft-ferromagnetism to superparamagnetism. In addition, when the Gd/Fe ratio was 15% (designated as GMIO-2), the GMIO-2 possessed the best superparamagnetism and highest magnetism. Subsequently, T1 and T2 values of GMIO-2 were measured through a series of turbo spin-echo images and then multi-spin echo sequence, respectively. Based on this, T1 and T2 relaxivities of GMIO-2 were calculated and were the highest (r1: 1.306 m M?1 s?1 and r2: 234.5 m M?1 s?1) when compared to other groups. The cytotoxicity of GMIO-2 was negligible under a wide range of dosages, thus exhibiting excellent cell biocompatibility. Moreover, GMIO-2 could quickly diffuse into cells, leading to its effective accumulation. The systemic delivery of GMIO-2 resulted in an excellent T1–T2 dual-mode MRI contrast effect in kidneys, which is expected to improve the diagnosis of kidney lesions. Therefore, this work provides a promising candidate for the development of a T1–T2 dual-mode MRI CA.
语种英语
出版者IOP Publishing
WOS记录号IOP:1748-6041-16-4-ABEF54
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/121881]  
专题中国科学院合肥物质科学研究院
通讯作者Chen,Peirong; Qian,Junchao; Wu,Zhengyan
作者单位1.University of Science and Technology of China, Hefei 230026, People’s Republic of China
2.Department of Applied Chemistry, School of Science, Anhui Agricultural University, Hefei 230036, People’s Republic of China
3.Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
4.Hefei Cancer Hospital, Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
5.School of Pharmacy, The Key Laboratory of Prescription Effect and Clinical Evaluation of State Administration of Traditional Chinese Medicine of China, Binzhou Medical University, Yantai 264003, People’s Republic of China
推荐引用方式
GB/T 7714
Miao,Yashuang,Chen,Peirong,Yan,Miao,et al. Highly sensitive T1–T2 dual-mode MRI probe based on ultra-small gadolinium oxide-decorated iron oxide nanocrystals[J]. Biomedical Materials,2021,16.
APA Miao,Yashuang.,Chen,Peirong.,Yan,Miao.,Xiao,Jianmin.,Hong,Biao.,...&Wu,Zhengyan.(2021).Highly sensitive T1–T2 dual-mode MRI probe based on ultra-small gadolinium oxide-decorated iron oxide nanocrystals.Biomedical Materials,16.
MLA Miao,Yashuang,et al."Highly sensitive T1–T2 dual-mode MRI probe based on ultra-small gadolinium oxide-decorated iron oxide nanocrystals".Biomedical Materials 16(2021).

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。