中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays

文献类型:期刊论文

作者Liu, Chao1,2; Bai, Chen1; Yu, Xianghua1; Yan, Shaohui1; Zhou, Yuan1,2; Li, Xing1,2; Min, Junwei1; Yang, Yanlong1; Dan, Dan1; Yao, Baoli1,2
刊名Optics Express
出版日期2021-02-15
卷号29期号:4页码:6158-6168
ISSN号10944087
DOI10.1364/OE.418707
产权排序1
英文摘要

Light-sheet fluorescence microscopy (LSFM) facilitates high temporal-spatial resolution, low photobleaching and phototoxicity for long-term volumetric imaging. However, when a high axial resolution or optical sectioning capability is required, the field of view (FOV) is limited. Here, we propose to generate a large FOV of light-sheet by scanning multiple focus-shifted Gaussian beam arrays (MGBA) while keeping the high axial resolution. The positions of the beam waists of the multiple Gaussian beam arrays are shifted in both axial and lateral directions in an optimized arranged pattern, and then scanned along the direction perpendicular to the propagation axis to form an extended FOV of light-sheet. Complementary beam subtraction method is also adopted to further improve axial resolution. Compared with the single Gaussian light-sheet method, the proposed method extends the FOV from 12 µm to 200 µm while sustaining the axial resolution of 0.73 µm. Both numerical simulation and experiment on samples are performed to verify the effectiveness of the method. © 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

语种英语
WOS记录号WOS:000619209800120
出版者OSA - The Optical Society
源URL[http://ir.opt.ac.cn/handle/181661/94442]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
作者单位1.State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and PrecisionMechanics, Chinese Academy of Sciences, Xi’an, Shaanxi; 710119, China;
2.University of Chinese Academy of Sciences, Beijing; 100049, China
推荐引用方式
GB/T 7714
Liu, Chao,Bai, Chen,Yu, Xianghua,et al. Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays[J]. Optics Express,2021,29(4):6158-6168.
APA Liu, Chao.,Bai, Chen.,Yu, Xianghua.,Yan, Shaohui.,Zhou, Yuan.,...&Yao, Baoli.(2021).Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays.Optics Express,29(4),6158-6168.
MLA Liu, Chao,et al."Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays".Optics Express 29.4(2021):6158-6168.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。