Multiple closed-loop control based on improved Smith predictor

文献类型:会议论文

作者Duan, Qianwen1,2,3; Ren, Wei1,2,3; Liu, Wansheng1,2; Mao, Yao1,2; Luo, Yong1,2,3; Wu, Shuiqin1,2,3
出版日期2019
会议日期June 26, 2018 - June 29, 2018
会议地点Chengdu, China
关键词Electro-optical control systems MEMS gyroscopes Improved Smith Predictor Disturbance suppression
卷号10838
DOI10.1117/12.2504921
页码108380I
英文摘要In classical electro-optical control systems, the double closed-loop control including speed feedback and position feedback is often used to enhance the closed-loop performance. As the system is subject to internal detection delays and external disturbances, the stability and tracking accuracy of system are greatly challenged. MEMS gyroscopes inertial sensor are widely used in electro-optical control systems due to their advantages of light weight, high resonant frequency, and short response time. However, the Analog-To-Digital conversion and self-filtering characteristics of the sensors determine that there is a certain detection delay, and the system also faces the interference caused by the mechanical resonance. To solve this problem, an improved Smith Predictor method based on inertial sensor-MEMS gyroscope is proposed. The original Smith Predictor is only used to eliminate the effect of delay. Base of that, we modify the predictor's structure and add a branch of disturbance observer to compensate the external disturbance. The control strategy and the formula derivation is given out. The experimental results show that the closed-loop bandwidth of the system's speed loop are significantly improved, and the method effectively improves the system's disturbance suppression performance. © 2019 COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only.
会议录Proceedings of SPIE 10838 - 9th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Advanced Optical Manufacturing Technologies
会议录出版者SPIE
文献子类会议论文
语种英语
ISSN号0277-786X
WOS研究方向Engineering, Manufacturing ; Optics
WOS记录号WOS:000459715700017
源URL[http://ir.ioe.ac.cn/handle/181551/9609]  
专题光电技术研究所_光电工程总体研究室(一室)
作者单位1.Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu; 610209, China;
2.Key Laboratory of Optical Engineering, Chinese Academy of Sciences, Chengdu; 610209, China;
3.University of Chinese Academy of Sciences, Beijing; 100039, China
推荐引用方式
GB/T 7714
Duan, Qianwen,Ren, Wei,Liu, Wansheng,et al. Multiple closed-loop control based on improved Smith predictor[C]. 见:. Chengdu, China. June 26, 2018 - June 29, 2018.

入库方式: OAI收割

来源:光电技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。