Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid
文献类型:期刊论文
作者 | Zhang, Qiaoxia3,4; Lyu, Haoyuan3,4; Li, Ning3,4; Liu, Qing3,4![]() |
刊名 | ELECTROCHIMICA ACTA
![]() |
出版日期 | 2020-09-10 |
卷号 | 354页码:9 |
关键词 | Thrombin Photoelectrochemical aptasensor TiO2/CuOx Perylene-3,4,9,10-tetracarboxylic acid |
ISSN号 | 0013-4686 |
DOI | 10.1016/j.electacta.2020.136774 |
通讯作者 | Wang, Xiutong() ; Qingyun, Liu(qyliu@sdust.edu.cn) |
英文摘要 | In this work, a sensitive signal-off photoelectrochemical (PEC) thrombin aptasensor with satisfying specificity is proposed, in which the evident initial photocurrent response is produced by the photoanode and the signal amplification strategy toward the target is based on the specific bio-affinity properties between thrombin and their aptamers. The photoanode was fabricated with uniform TiO2 nanotube arrays decorated with CuOx and perylene-3,4,9,10-tetracarboxylic acid (PTCA). After the decoration of CuOx and PTCA, both possessing a strong absorption in visible region, the photocurrent response is improved greatly. Pt nanoparticles were modified on the photoanode electrode to immobilize thrombin aptamers, which could obviously improve the conductivity of the photoanode electrode owing to the excellent conductivity of Pt nanoparticles. The non-conductive complex leads to dramatical decrease in the photocurrent value due to the steric hinder effect. Based on the joint action of evident photocurrent response of photoanode and significant signal amplification strategy, the aptasensor in this project offers a wide linear range from 0.0003 nM to 10 nM, with a detection limit (3S/N) of thrombin down to 55 fM. Moreover, the as-fabricated aptasensor exhibits acceptable selectivity and stability, providing a meaningful attempt for the detection of thrombin. (C) 2020 Elsevier Ltd. All rights reserved. |
资助项目 | National Natural Science Foundation of China[21971152] ; Natural Science Foundation of Shandong Province[ZR2018MB002] |
WOS研究方向 | Electrochemistry |
语种 | 英语 |
WOS记录号 | WOS:000569145000012 |
出版者 | PERGAMON-ELSEVIER SCIENCE LTD |
源URL | [http://ir.qdio.ac.cn/handle/337002/168798] ![]() |
专题 | 海洋研究所_海洋腐蚀与防护研究发展中心 |
通讯作者 | Wang, Xiutong; Qingyun, Liu |
作者单位 | 1.Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China 2.Chinese Acad Sci, Key Lab Marine Environm Corros & Biofouling, Inst Oceanol, Qingdao 266071, Peoples R China 3.Shandong Univ Sci & Technol, Coll Chem & Biol Engn, State Key Lab Min Disaster Prevent & Control Cofo, Qingdao 266590, Peoples R China 4.Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China 5.Liaocheng Univ, Shandong Prov Key Lab, Collaborat Innovat Ctr Chem Energy Storage & Nove, Sch Chem & Chem Engn, Liaocheng 252059, Shandong, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Qiaoxia,Lyu, Haoyuan,Li, Ning,et al. Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid[J]. ELECTROCHIMICA ACTA,2020,354:9. |
APA | Zhang, Qiaoxia.,Lyu, Haoyuan.,Li, Ning.,Liu, Qing.,Zhang, Xianxi.,...&Qingyun, Liu.(2020).Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid.ELECTROCHIMICA ACTA,354,9. |
MLA | Zhang, Qiaoxia,et al."Visible light driven photoelectrochemical thrombin aptasensor based on uniform TiO2 nanotube arrays modified with CuOx and perylene-3,4,9,10-tetracarboxylic acid".ELECTROCHIMICA ACTA 354(2020):9. |
入库方式: OAI收割
来源:海洋研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。