Mobile hydrogen monitoring in the wall of hydrogenation reactors
文献类型:期刊论文
作者 | Yu, G; Zhang, XY; Du, YL |
刊名 | CORROSION
![]() |
出版日期 | 2001 |
卷号 | 57期号:1页码:71-77 |
关键词 | hydrogen distribution hydrogen embrittlement hydrogen permeation hydrogenation reactor hydrogen sensor nondestructive test technique |
ISSN号 | 0010-9312 |
通讯作者 | Yu, G() |
英文摘要 | A test technique was developed for in-situ, instantaneous, and nondestructive inspection of the distribution of mobile hydrogen in the wall of a hydrogenation reactor operating at an elevated temperature and high pressure. The base current density of the developed sensor was < 0.6 muA/cm(2) at cooling water temperatures below 313 K (40degreesC). The steady current density, i(infinity), of atomic hydrogen oxidation needed calibrating from the direct-measuring sensor signal, i(sen). The calibration equation could be expressed as i(infinity) = 1.2 i(sen). Its factor 1.2 corrects the difference in the direction change of hydrogen diffusion from one dimension in the steel wall to three dimensions in the space between the steel external surface and the external side of the Pd alloy in the sensor. The temperature of the cooling water of the sensor obviously influenced the steady permeation current density. Results of the study showed that the temperature of the sensor should be kept constant so as to assure measurement accuracy. The specifications of the developed probe available for elevated temperature are presented in this paper. Inspection results of hydrogen concentration obtained from an operating hydrogenation reactor are displayed. |
WOS研究方向 | Materials Science ; Metallurgy & Metallurgical Engineering |
语种 | 英语 |
WOS记录号 | WOS:000176355600009 |
出版者 | NATL ASSN CORROSION ENG |
源URL | [http://ir.imr.ac.cn/handle/321006/111906] ![]() |
专题 | 金属研究所_中国科学院金属研究所 |
通讯作者 | Yu, G |
作者单位 | 1.Chinese Acad Sci, Inst Corros & Protect Met, State Key Lab Corros & Protect, Beijing, Peoples R China 2.Chinese Acad Sci, Inst Met Res, State Key Lab Corros & Protect, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Yu, G,Zhang, XY,Du, YL. Mobile hydrogen monitoring in the wall of hydrogenation reactors[J]. CORROSION,2001,57(1):71-77. |
APA | Yu, G,Zhang, XY,&Du, YL.(2001).Mobile hydrogen monitoring in the wall of hydrogenation reactors.CORROSION,57(1),71-77. |
MLA | Yu, G,et al."Mobile hydrogen monitoring in the wall of hydrogenation reactors".CORROSION 57.1(2001):71-77. |