中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
In vitro degradation and biocompatibility evaluation of fully biobased thermoplastic elastomers consisting of poly(beta-myrcene) and poly(L-lactide) as stent coating

文献类型:期刊论文

作者Wei, Zhiyong2; Wang, Wenhuan2; Zhou, Cheng2; Jin, Chenhao2; Leng, Xuefei2; Li, Yang2; Zhang, Xing1,3; Chen, Shanshan3; Zhang, Bingchun3; Yang, Ke3
刊名POLYMER DEGRADATION AND STABILITY
出版日期2020-09-01
卷号179页码:10
ISSN号0141-3910
关键词Drug eluting stent Coating Poly(beta-myrcene)-poly(L-lactide) Thermoplastic elastomers
DOI10.1016/j.polymdegradstab.2020.109254
通讯作者Leng, Xuefei(lengxuefei@dlut.edu.cn) ; Chen, Shanshan(sschen@imr.ac.cn)
英文摘要Currently coronary stent coating materials focus on biodegradable polymers requiring excellent performances, including biodegradability, cytocompatibility and hemocompatibility as well as ductility. To endow poly(L-lactide) (PLLA) with good ductility as stent coating, two kinds of high branched PLLA grafted copolymers with introduction of biobased poly(beta-myrcene) rubber segments were developed towards sent coating. The impacts of topological architectures (including linear comb and star comb) on physical properties, hydrolytic and enzymatic degradation behaviors, cytocompatibility, hemocompatibility and coating morphology were investigated. It was found that the nonbiodegradable poly(beta-myrcene) rubber segments delayed the degradation rate, and further decreased with more complex architectures. Proteinase K accelerated enzymatic degradation compared with hydrolytic degradation. Biocompatibility testing showed that the fully biobased thermoplastic elastomers possessed good cytocompatibility and hemocompatibility. Morphological characterization of stent coatings indicated that the linear comb and star comb PLLA grafted copolymers improved the surface smooth of pure PLLA coating. Thus, these highly branched fully biobased thermoplastic elastomers are promising to as potential coating materials in drug eluting stent. (C) 2020 Elsevier Ltd. All rights reserved.
资助项目National Key R&D Program of China[2018YFC1105500 (2018YFC1105503)] ; Joint Research Fund Liaoning-Shenyang National Laboratory for Materials Science[20180510037] ; Fundamental Research Funds for the Central Universities[DUT19LAB27]
WOS研究方向Polymer Science
语种英语
出版者ELSEVIER SCI LTD
WOS记录号WOS:000564499500004
资助机构National Key R&D Program of China ; Joint Research Fund Liaoning-Shenyang National Laboratory for Materials Science ; Fundamental Research Funds for the Central Universities
源URL[http://ir.imr.ac.cn/handle/321006/140434]  
专题金属研究所_中国科学院金属研究所
通讯作者Leng, Xuefei; Chen, Shanshan
作者单位1.Univ Sci & Technol China, Sch Mat Sci & Engn, Shenyang 110016, Liaoning, Peoples R China
2.Dalian Univ Technol, Sch Chem Engn, Dept Polymer Sci & Engn, State Key Lab Fine Chem,Liaoning Key Lab Polymer, Dalian 116024, Peoples R China
3.Chinese Acad Sci, Inst Met Res, 72 Wenhua Rd, Shenyang 110016, Peoples R China
推荐引用方式
GB/T 7714
Wei, Zhiyong,Wang, Wenhuan,Zhou, Cheng,et al. In vitro degradation and biocompatibility evaluation of fully biobased thermoplastic elastomers consisting of poly(beta-myrcene) and poly(L-lactide) as stent coating[J]. POLYMER DEGRADATION AND STABILITY,2020,179:10.
APA Wei, Zhiyong.,Wang, Wenhuan.,Zhou, Cheng.,Jin, Chenhao.,Leng, Xuefei.,...&Yang, Ke.(2020).In vitro degradation and biocompatibility evaluation of fully biobased thermoplastic elastomers consisting of poly(beta-myrcene) and poly(L-lactide) as stent coating.POLYMER DEGRADATION AND STABILITY,179,10.
MLA Wei, Zhiyong,et al."In vitro degradation and biocompatibility evaluation of fully biobased thermoplastic elastomers consisting of poly(beta-myrcene) and poly(L-lactide) as stent coating".POLYMER DEGRADATION AND STABILITY 179(2020):10.

入库方式: OAI收割

来源:金属研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。